2018JAPANES JOURNAL OF MEDICAL INSTRUMENTATIONOpen access

Development of a Novel Hygiene Monitoring System Based on the Detection of Total Adenylate (ATP+ADP+AMP)

Mikio Bakke, Nobuyoshi Sato, Shigeya Suzuki, Erina Kirihara, Mariko Watanabe, Shigeru Mikami

Open full text 2 citations

Abstract

Adenosine triphosphate (ATP) tests are commonly used for cleanliness verification. However, since ATP is hydrolyzed to adenosine diphosphate (ADP) and adenosine monophosphate (AMP), total adenylate (ATP+ADP+AMP, A3) could be more reliable indicators. In this study, a novel enzymatic method to measure A3 was developed based on luciferin-luciferase assay with the combination of two enzymes, pyruvate kinase and pyruvate phosphate dikinase, which can convert ADP and AMP into ATP, respectively. The A3 method afforded equivalent linear calibration curves between the measurement output (Relative Light Units) and each of the amounts of ATP, ADP and AMP. The assays using conventional ATP tests and the A3 tests demonstrated that ATP in hemolysate was decomposed easily, on the other hand, the amounts of A3 were clearly maintained. Regarding sweat samples, the amount of A3 was 20 times higher than that of ATP. Moreover, the investigation for high touch surface samples showed good correlations between the A3 method and viable bacteria counts, and the amount of A3 was about 8 times higher than that of ATP on average. Therefore, the A3 tests appeared to be more reliable for the assessment of sanitation in healthcare settings than the conventional ATP assay.

Open-access reader

About this research paper

What this paper is about

Adenosine triphosphate (ATP) tests are commonly used for cleanliness verification. However, since ATP is hydrolyzed to adenosine diphosphate (ADP) and adenosine monophosphate (AMP), total adenylate (ATP+ADP+AMP, A3) could be more reliable indicators. In this study, a novel enzymatic method to measure A3 was developed based on luciferin-luciferase assay with the combination of two enzymes, pyruvate kinase and pyruvate phosphate dikinase, which can convert ADP and AMP into ATP, respectively. The A3 method afforded equivalent linear calibration curves between the measurement output (Relative Light Units) and each of the amounts of ATP, ADP and AMP. The assays using conventional ATP tests and the A3 tests demonstrated that ATP in hemolysate was decomposed easily, on the other hand, the amounts of A3 were clearly maintained. Regarding sweat samples, the amount of A3 was 20 times higher than that of ATP. Moreover, the investigation for high touch surface samples showed good correlations between the A3 method and viable bacteria counts, and the amount of A3 was about 8 times higher than that of ATP on average. Therefore, the A3 tests appeared to be more reliable for the assessment of sanitation in healthcare settings than the conventional ATP assay.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Adenosine triphosphate (ATP) tests are commonly used for cleanliness verification. However, since ATP is hydrolyzed to adenosine diphosphate (ADP) and adenosine monophosphate (AMP), total adenylate (ATP+ADP+AMP, A3) could be more reliable indicators. In this study, a novel enzymatic method to measure A3 was developed based on luciferin-luciferase assay with the combination of two enzymes, pyruvate kinase and pyruvate phosphate dikinase, which can convert ADP and AMP into ATP, respectively. The A3 method afforded equivalent linear calibration curves between the measurement output (Relative Light Units) and each of the amounts of ATP, ADP and AMP. The assays using conventional ATP tests and the A3 tests demonstrated that ATP in hemolysate was decomposed easily, on the other hand, the amounts of A3 were clearly maintained. Regarding sweat samples, the amount of A3 was 20 times higher than that of ATP. Moreover, the investigation for high touch surface samples showed good correlations between the A3 method and viable bacteria counts, and the amount of A3 was about 8 times higher than that of ATP on average. Therefore, the A3 tests appeared to be more reliable for the assessment of sanitation in healthcare settings than the conventional ATP assay.

Key concepts: Adenylate kinase, Adenosine triphosphate, Adenosine diphosphate, Adenosine monophosphate, ATP–ADP translocase, ATP hydrolysis, Biochemistry, Adenosine

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of a Novel Hygiene Monitoring System Based on the Detection of Total Adenylate (ATP+ADP+AMP) — Research Paper | ScholarLens