Simultaneous determination of arbutin and hydroquinone in different herbal slimming products by Gas Chromatography-Mass Spectrometry
B Dursunoğlu, Hafize Yuca, Zühal Güvenalp, Sefa Gözcü, Bilal Yılmaz
Abstract
Open-access reader
B Dursunoğlu, Hafize Yuca, Zühal Güvenalp, Sefa Gözcü, Bilal Yılmaz
Abstract
Open-access reader
OBJECTIVES: The aim of our study was to develop a simple, precise, sensitive and specific method for the simultaneous determination of arbutin and hydroquinone in different herbal slimming products using GC-MS. MATERIALS AND METHODS: The methanol and aqueous extracts of nine herbal slimming products in Turkey were evaluated for analysis of arbutin and hydroquinone using GC-MS method. RESULTS: The retention times of arbutin and hydroquinone were found as 11.32 and 5.44 min, respectively. The linear ranges in this method were 5-500 ng/mL for arbutin and hydroquinone, respectively. The intra- and inter-day precisions, expressed as the relative standard deviation, were less than 1.94 and 2.73%, determined from quality control samples for arbutin and hydroquinone, and accuracy was within 1.13 and 2.56% in terms of relative error, respectively. The limit of detection and quantification were 0.555 and 1.665 ng/mL for arbutin, and 0.031 and 0.093 ng/mL for hydroquinone, respectively. CONCLUSION: The developed method can be used for routine quality control analysis of arbutin and hydroquinone in different herbal slimming products.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVES: The aim of our study was to develop a simple, precise, sensitive and specific method for the simultaneous determination of arbutin and hydroquinone in different herbal slimming products using GC-MS. MATERIALS AND METHODS: The methanol and aqueous extracts of nine herbal slimming products in Turkey were evaluated for analysis of arbutin and hydroquinone using GC-MS method. RESULTS: The retention times of arbutin and hydroquinone were found as 11.32 and 5.44 min, respectively. The linear ranges in this method were 5-500 ng/mL for arbutin and hydroquinone, respectively. The intra- and inter-day precisions, expressed as the relative standard deviation, were less than 1.94 and 2.73%, determined from quality control samples for arbutin and hydroquinone, and accuracy was within 1.13 and 2.56% in terms of relative error, respectively. The limit of detection and quantification were 0.555 and 1.665 ng/mL for arbutin, and 0.031 and 0.093 ng/mL for hydroquinone, respectively. CONCLUSION: The developed method can be used for routine quality control analysis of arbutin and hydroquinone in different herbal slimming products.
Key concepts: Arbutin, Chromatography, Hydroquinone, Gas chromatography–mass spectrometry, Mass spectrometry, Chemistry, Gas chromatography, Traditional medicine