2018Journal of International Medical ResearchOpen access

Image-guided vacuum-assisted breast biopsy in the diagnosis of breast microcalcifications

Jun Liu, Linping Huang

Open full text 19 citations

Abstract

Objective The present study was performed to assess the accuracy and clinical value of image-guided vacuum-assisted breast biopsy in the diagnosis of mammography-detected breast microcalcifications. Methods This prospective study involved 100 patients with suspicious mammography-detected microcalcifications who underwent image-guided vacuum-assisted breast biopsies from January 2013 to October 2016. Stereotactic vacuum-assisted breast biopsy (SVAB) was performed in 64 patients, and ultrasound (US)-guided vacuum-assisted breast biopsy (US-VAB) was performed in 36 patients in whom application of SVAB was difficult. The microcalcifications were detectable by mammography or US. The mean follow-up duration was 32 months (range, 9-57 months). The biopsy results were correlated with the pathological examination results. Results The positive predictive value of microcalcifications detected by mammography and US in the diagnosis of breast cancer was 37.0% (37/100) and 52.8% (19/36), respectively. The negative predictive value of microcalcifications detected by US in the diagnosis of breast cancer was 71.9% (46/64). No recurrence was observed in the 37 patients with breast cancer. No evidence of malignancy was found among the 63 patients with benign lesions. Conclusion Image-guided vacuum-assisted breast biopsy is accurate and minimally invasive. It can be used as a safe approach for diagnosis in patients with breast microcalcifications.

About this research paper

What this paper is about

Objective The present study was performed to assess the accuracy and clinical value of image-guided vacuum-assisted breast biopsy in the diagnosis of mammography-detected breast microcalcifications. Methods This prospective study involved 100 patients with suspicious mammography-detected microcalcifications who underwent image-guided vacuum-assisted breast biopsies from January 2013 to October 2016. Stereotactic vacuum-assisted breast biopsy (SVAB) was performed in 64 patients, and ultrasound (US)-guided vacuum-assisted breast biopsy (US-VAB) was performed in 36 patients in whom application of SVAB was difficult. The microcalcifications were detectable by mammography or US. The mean follow-up duration was 32 months (range, 9-57 months). The biopsy results were correlated with the pathological examination results. Results The positive predictive value of microcalcifications detected by mammography and US in the diagnosis of breast cancer was 37.0% (37/100) and 52.8% (19/36), respectively. The negative predictive value of microcalcifications detected by US in the diagnosis of breast cancer was 71.9% (46/64). No recurrence was observed in the 37 patients with breast cancer. No evidence of malignancy was found among the 63 patients with benign lesions. Conclusion Image-guided vacuum-assisted breast biopsy is accurate and minimally invasive. It can be used as a safe approach for diagnosis in patients with breast microcalcifications.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective The present study was performed to assess the accuracy and clinical value of image-guided vacuum-assisted breast biopsy in the diagnosis of mammography-detected breast microcalcifications. Methods This prospective study involved 100 patients with suspicious mammography-detected microcalcifications who underwent image-guided vacuum-assisted breast biopsies from January 2013 to October 2016. Stereotactic vacuum-assisted breast biopsy (SVAB) was performed in 64 patients, and ultrasound (US)-guided vacuum-assisted breast biopsy (US-VAB) was performed in 36 patients in whom application of SVAB was difficult. The microcalcifications were detectable by mammography or US. The mean follow-up duration was 32 months (range, 9-57 months). The biopsy results were correlated with the pathological examination results. Results The positive predictive value of microcalcifications detected by mammography and US in the diagnosis of breast cancer was 37.0% (37/100) and 52.8% (19/36), respectively. The negative predictive value of microcalcifications detected by US in the diagnosis of breast cancer was 71.9% (46/64). No recurrence was observed in the 37 patients with breast cancer. No evidence of malignancy was found among the 63 patients with benign lesions. Conclusion Image-guided vacuum-assisted breast biopsy is accurate and minimally invasive. It can be used as a safe approach for diagnosis in patients with breast microcalcifications.

Key concepts: Medicine, Mammography, Breast cancer, Biopsy, Radiology, Breast biopsy, Malignancy, Microcalcification

Related papers

Back to paper searchBrowse research topicsOriginal source
Image-guided vacuum-assisted breast biopsy in the diagnosis of breast microcalcifications — Research Paper | ScholarLens