2018Unpublished venueRequires access

Real-time detection of 192Ir gamma-ray source positon using organic scintillator array sensor in HDR brachytherapy

Hyun Young Shin, Jae Hyung Park, Hyungi Byun, Si Won Song, Jee Ye Kim, Young Beom Song, Bongsoo Lee, Sang Hun Shin

Open publisher page 0 citations

Abstract

In this study, we fabricated an organic scintillator array sensor (OSAS) based the array of organic scintillators. The scintillator array of OSAS for detecting positions of 192Ir gamma-ray source was fabricated using four types of organic scintillators, which emit the scintillating lights of different wavelength, respectively. To evaluate the performance of the OSAS, 192Ir gamma-ray source employed in a HDR brachytherapy was used. In this research, the spectra were measured with positions of 192Ir gamma-ray source which was moved at intervals of 5 mm and 10 mm using the OSAS. The experimental results show that the proposed OSAS can measure and discriminate the wavelength of scintillating lights generated in the OSAS according to the positions of 192Ir gamma-ray source. It is expected that the OSAS can used to detect positions of 192Ir gamma-ray source during a HDR brachytherapy. Further studies are planned to fabricate the OSAS with the different intervals of movements and the small size of organic scintillators.

About this research paper

What this paper is about

In this study, we fabricated an organic scintillator array sensor (OSAS) based the array of organic scintillators. The scintillator array of OSAS for detecting positions of 192Ir gamma-ray source was fabricated using four types of organic scintillators, which emit the scintillating lights of different wavelength, respectively. To evaluate the performance of the OSAS, 192Ir gamma-ray source employed in a HDR brachytherapy was used. In this research, the spectra were measured with positions of 192Ir gamma-ray source which was moved at intervals of 5 mm and 10 mm using the OSAS. The experimental results show that the proposed OSAS can measure and discriminate the wavelength of scintillating lights generated in the OSAS according to the positions of 192Ir gamma-ray source. It is expected that the OSAS can used to detect positions of 192Ir gamma-ray source during a HDR brachytherapy. Further studies are planned to fabricate the OSAS with the different intervals of movements and the small size of organic scintillators.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, we fabricated an organic scintillator array sensor (OSAS) based the array of organic scintillators. The scintillator array of OSAS for detecting positions of 192Ir gamma-ray source was fabricated using four types of organic scintillators, which emit the scintillating lights of different wavelength, respectively. To evaluate the performance of the OSAS, 192Ir gamma-ray source employed in a HDR brachytherapy was used. In this research, the spectra were measured with positions of 192Ir gamma-ray source which was moved at intervals of 5 mm and 10 mm using the OSAS. The experimental results show that the proposed OSAS can measure and discriminate the wavelength of scintillating lights generated in the OSAS according to the positions of 192Ir gamma-ray source. It is expected that the OSAS can used to detect positions of 192Ir gamma-ray source during a HDR brachytherapy. Further studies are planned to fabricate the OSAS with the different intervals of movements and the small size of organic scintillators.

Key concepts: Scintillator, Radioactive source, Brachytherapy, Gamma ray, Optics, Physics, Wavelength, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Real-time detection of 192Ir gamma-ray source positon using organic scintillator array sensor in HDR brachytherapy — Research Paper | ScholarLens