Measurement of the angular correlation between the two gamma rays emitted in the radioactive decays of a $^{60}$Co source with two NaI(Tl) scintillator

Amato, E. C., Alessia Anelli, Barbieri, M., Cataldi, D., Cellamare, V., Davide Cerasole, Conserva, F., De Gaetano, S., Depalo, D., Digennaro, A., Fiorente, E., Gargano, F., Gatti, D., Loizzo, P., Loparco, F., Mele, O., Nicola Nicassio, Perfetto, G., Pillera, R., Pirlo, R., Schygulla, E., Troiano, D.

Open full text 0 citations

Abstract

We implemented a didactic experiment to study the angular correlation between the two gamma rays emitted in typical $^{60}$Co radioactive decays. We used two NaI(Tl) scintillators, already available in our laboratory, and a low-activity $^{60}$Co source. The detectors were mounted on two rails, with the source at their center. The first rail was fixed, while the second could be rotated around the source. We performed several measurements by changing the angle between the two scintillators in the range from $90^\circ$ to $180^\circ$. Dedicated background runs were also performed, removing the source from the experimental setup. We found that the signal rate increases with the angular separation between the two scintillators, with small discrepancies from the theoretical expectations.

Open-access reader

About this research paper

What this paper is about

We implemented a didactic experiment to study the angular correlation between the two gamma rays emitted in typical $^{60}$Co radioactive decays. We used two NaI(Tl) scintillators, already available in our laboratory, and a low-activity $^{60}$Co source. The detectors were mounted on two rails, with the source at their center. The first rail was fixed, while the second could be rotated around the source. We performed several measurements by changing the angle between the two scintillators in the range from $90^\circ$ to $180^\circ$. Dedicated background runs were also performed, removing the source from the experimental setup. We found that the signal rate increases with the angular separation between the two scintillators, with small discrepancies from the theoretical expectations.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We implemented a didactic experiment to study the angular correlation between the two gamma rays emitted in typical $^{60}$Co radioactive decays. We used two NaI(Tl) scintillators, already available in our laboratory, and a low-activity $^{60}$Co source. The detectors were mounted on two rails, with the source at their center. The first rail was fixed, while the second could be rotated around the source. We performed several measurements by changing the angle between the two scintillators in the range from $90^\circ$ to $180^\circ$. Dedicated background runs were also performed, removing the source from the experimental setup. We found that the signal rate increases with the angular separation between the two scintillators, with small discrepancies from the theoretical expectations.

Key concepts: Scintillator, Physics, Radioactive source, Gamma ray, Range (aeronautics), Detector, Optics, Nuclear physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of the angular correlation between the two gamma rays emitted in the radioactive decays of a $^{60}$Co source with two NaI(Tl) scintillator — Research Paper | ScholarLens