Effect of Ionic and Non-Ionic Contrast Media on Aggregation of Red Blood Cells in Vitro
Raili Raininko, S.-L. Ylinen
Abstract
Raili Raininko, S.-L. Ylinen
Abstract
Fresh human blood without additives, and contrast medium were mixed and examined immediately by light microscopy in a non-flowing state. Sodium meglumine diatrizoate, meglumine diatrizoate, meglumine iodamide, sodium meglumine ioxaglate, iopromide, iopamidol, iohexol, and metrizamide were tested/in concentrations of 300 mg I/ml. Physiologic saline and 5? glucose were used as controls. All media were tested in a randomized order with blood samples from 23 volunteers. No aggregation was detected in physiologic saline, and few rouleaux were found in ionic contrast media. Irregular red cell aggregates were found in all low-osmolal contrast media: in 17 per cent of the specimens in ioxaglate, in 52 per cent in metrizamide, and in 78 to 100 per cent in other non-ionic media. Irregular aggregates were seen in all specimens with glucose. It remains to be demonstrated whether or not the irregular aggregation of human red cells in non-ionic contrast media has clinical significance. Iohexol was also tested with bloo...
OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Fresh human blood without additives, and contrast medium were mixed and examined immediately by light microscopy in a non-flowing state. Sodium meglumine diatrizoate, meglumine diatrizoate, meglumine iodamide, sodium meglumine ioxaglate, iopromide, iopamidol, iohexol, and metrizamide were tested/in concentrations of 300 mg I/ml. Physiologic saline and 5? glucose were used as controls. All media were tested in a randomized order with blood samples from 23 volunteers. No aggregation was detected in physiologic saline, and few rouleaux were found in ionic contrast media. Irregular red cell aggregates were found in all low-osmolal contrast media: in 17 per cent of the specimens in ioxaglate, in 52 per cent in metrizamide, and in 78 to 100 per cent in other non-ionic media. Irregular aggregates were seen in all specimens with glucose. It remains to be demonstrated whether or not the irregular aggregation of human red cells in non-ionic contrast media has clinical significance. Iohexol was also tested with bloo...
Key concepts: Metrizamide, Iohexol, Iopromide, Iopamidol, Diatrizoate Meglumine, Meglumine, Medicine, Diatrizoate