2017Acta Polytechnica CTU ProceedingsOpen access

GEOMETRICAL OPTIMIZATION OF DENTAL IMPLANTS WITH REGARD TO OSSEOINTEGRATION

Luboš Řehounek, František Denk, Aleš Jíra

Open full text 2 citations

Abstract

A newly developed reference dental implant specimen type was subjected to numerical simulations of osseointegration. The goal of these tests was to optimize the geometry of the implant so as to reduce local stress concentrations and provide a better flow of stress through the whole implant body. Conditions for osseointegration were considered when evaluating the anchoring system of the implant in regard to its placement in the human cancellous and cortical bone. Numerical simulations showed that stress concentrations occur mostly in the upper cylindrical part of the implant. By increasing the width of this cylindrical part, we were able to reduce the maximum values of von-Mises stress by 20 %.

Open-access reader

About this research paper

What this paper is about

A newly developed reference dental implant specimen type was subjected to numerical simulations of osseointegration. The goal of these tests was to optimize the geometry of the implant so as to reduce local stress concentrations and provide a better flow of stress through the whole implant body. Conditions for osseointegration were considered when evaluating the anchoring system of the implant in regard to its placement in the human cancellous and cortical bone. Numerical simulations showed that stress concentrations occur mostly in the upper cylindrical part of the implant. By increasing the width of this cylindrical part, we were able to reduce the maximum values of von-Mises stress by 20 %.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A newly developed reference dental implant specimen type was subjected to numerical simulations of osseointegration. The goal of these tests was to optimize the geometry of the implant so as to reduce local stress concentrations and provide a better flow of stress through the whole implant body. Conditions for osseointegration were considered when evaluating the anchoring system of the implant in regard to its placement in the human cancellous and cortical bone. Numerical simulations showed that stress concentrations occur mostly in the upper cylindrical part of the implant. By increasing the width of this cylindrical part, we were able to reduce the maximum values of von-Mises stress by 20 %.

Key concepts: Osseointegration, von Mises yield criterion, Implant, Cancellous bone, Materials science, Dental implant, Cortical bone, Stress (linguistics)

Related papers

Back to paper searchBrowse research topicsOriginal source
GEOMETRICAL OPTIMIZATION OF DENTAL IMPLANTS WITH REGARD TO OSSEOINTEGRATION — Research Paper | ScholarLens