2014Bio-Medical Materials and EngineeringRequires access

Finite Element Analysis of Dental Implant Neck Effects on Primary Stability and Osseointegration in a Type IV Bone Mandible

You‐Min Huang, I‐Chiang Chou, Cho‐Pei Jiang, Yi-Syun Wu, Shyh‐Yuan Lee

Open publisher page 32 citations

Abstract

The purpose of this study is to investigate the effect of implant neck design and cortical bone thickness by means of 3-D linearly elastic finite element analysis and to analyze primary and secondary stability of clinical evidence based on micromotion and principal stress. Four commercial dental implants, comparable in size, for a type IV bone and mandibular segments were created. Various parameters were considered, including the osseointegration condition (non- and full bonded), force direction (vertical and horizontal) and cortical bone thickness (0.3, 0.5 and 1mm). The force was considered a static load applied at the top of the platform. The magnitudes of the vertical and horizontal loading direction were 500 N and 250 N. Micromotion and principal stresses were employed to evaluate the failure of osseointegration and bone overloading, respectively. The results show that Maximum stress of the peri-implant bone decreased as cortical bone thickness increased. The stress concentration regions were located at the implant neck between the cortical bone and cancellous bone. The micromotion level in full osseointegration is less than that in non-osseointegration and it also decreases as a increasing of cortical bone thickness. Consequently, cortical bone thickness is a key factor for primary stability.

About this research paper

What this paper is about

The purpose of this study is to investigate the effect of implant neck design and cortical bone thickness by means of 3-D linearly elastic finite element analysis and to analyze primary and secondary stability of clinical evidence based on micromotion and principal stress. Four commercial dental implants, comparable in size, for a type IV bone and mandibular segments were created. Various parameters were considered, including the osseointegration condition (non- and full bonded), force direction (vertical and horizontal) and cortical bone thickness (0.3, 0.5 and 1mm). The force was considered a static load applied at the top of the platform. The magnitudes of the vertical and horizontal loading direction were 500 N and 250 N. Micromotion and principal stresses were employed to evaluate the failure of osseointegration and bone overloading, respectively. The results show that Maximum stress of the peri-implant bone decreased as cortical bone thickness increased. The stress concentration regions were located at the implant neck between the cortical bone and cancellous bone. The micromotion level in full osseointegration is less than that in non-osseointegration and it also decreases as a increasing of cortical bone thickness. Consequently, cortical bone thickness is a key factor for primary stability.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study is to investigate the effect of implant neck design and cortical bone thickness by means of 3-D linearly elastic finite element analysis and to analyze primary and secondary stability of clinical evidence based on micromotion and principal stress. Four commercial dental implants, comparable in size, for a type IV bone and mandibular segments were created. Various parameters were considered, including the osseointegration condition (non- and full bonded), force direction (vertical and horizontal) and cortical bone thickness (0.3, 0.5 and 1mm). The force was considered a static load applied at the top of the platform. The magnitudes of the vertical and horizontal loading direction were 500 N and 250 N. Micromotion and principal stresses were employed to evaluate the failure of osseointegration and bone overloading, respectively. The results show that Maximum stress of the peri-implant bone decreased as cortical bone thickness increased. The stress concentration regions were located at the implant neck between the cortical bone and cancellous bone. The micromotion level in full osseointegration is less than that in non-osseointegration and it also decreases as a increasing of cortical bone thickness. Consequently, cortical bone thickness is a key factor for primary stability.

Key concepts: Osseointegration, Cortical bone, Implant, Materials science, Cancellous bone, Dental implant, Mandible (arthropod mouthpart), Dentistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Finite Element Analysis of Dental Implant Neck Effects on Primary Stability and Osseointegration in a Type IV Bone Mandible — Research Paper | ScholarLens