2017Annals of HepatologyOpen access

Rotational Thromboelastometry or Conventional Coagulation Tests in Liver Transplantation: Comparing Blood Loss, Transfusions, and Cost

Laura Smart, Khalid Mumtaz, Danielle Scharpf, Nicole O’Bleness Gray, Daniel Traetow, Sylvester M. Black, Anthony Michaels, Elmahdi Elkhammas, Robert M. Kirkpatrick, A. James Hanje

Open full text 83 citations

Abstract

INTRODUCTION: Orthotopic liver transplantation (OLT) can be associated with significant bleeding requiring multiple blood product transfusions. Rotational thromboelastometry (ROTEM) is a point-of-care device that has been used to monitor coagulation during OLT. Whether it reduces blood loss/transfusions during OLT remains controversial. MATERIALS AND METHODS: We aim to compare ROTEM with conventional coagulation tests (aPTT, PT, INR, platelet count, fibrinogen) to guide transfusion of platelets, cryoprecipitate, and fresh frozen plasma (FFP) during OLT over 3 years. Thirty-four patients who had transfusions guided by ROTEM were compared to 34 controls who received transfusions guided by conventional coagulation tests (CCT). Intraoperative blood loss, type/ amount of blood products transfused, and direct costs were compared between the two groups. RESULTS: The ROTEM group had significantly less intra-operative blood loss (2.0 vs. 3.0 L, p = 0.04) and fresh frozen plasma (FFP) transfusion (4 units vs. 6.5 units, p = 0.015) compared to the CCT group (2.0L vs. 3.0L, p = 0.04). However, total number of patients transfused cryoprecipitate was increased in ROTEM (n = 25;73%) as compared to CCT (n = 19; 56%), p = 0.033. The direct cost of blood products plus testing was reduced in the ROTEM group ($113,142.89 vs. $127,814.77). CONCLUSION: In conclusion implementation of a ROTEM-guided transfusion algorithm resulted in a reduction in intra-operative blood loss, FFP transfusion and a decrease in direct cost during OLT. ROTEM is a useful and safe point of care device in OLT setting.

Open-access reader

About this research paper

What this paper is about

INTRODUCTION: Orthotopic liver transplantation (OLT) can be associated with significant bleeding requiring multiple blood product transfusions. Rotational thromboelastometry (ROTEM) is a point-of-care device that has been used to monitor coagulation during OLT. Whether it reduces blood loss/transfusions during OLT remains controversial. MATERIALS AND METHODS: We aim to compare ROTEM with conventional coagulation tests (aPTT, PT, INR, platelet count, fibrinogen) to guide transfusion of platelets, cryoprecipitate, and fresh frozen plasma (FFP) during OLT over 3 years. Thirty-four patients who had transfusions guided by ROTEM were compared to 34 controls who received transfusions guided by conventional coagulation tests (CCT). Intraoperative blood loss, type/ amount of blood products transfused, and direct costs were compared between the two groups. RESULTS: The ROTEM group had significantly less intra-operative blood loss (2.0 vs. 3.0 L, p = 0.04) and fresh frozen plasma (FFP) transfusion (4 units vs. 6.5 units, p = 0.015) compared to the CCT group (2.0L vs. 3.0L, p = 0.04). However, total number of patients transfused cryoprecipitate was increased in ROTEM (n = 25;73%) as compared to CCT (n = 19; 56%), p = 0.033. The direct cost of blood products plus testing was reduced in the ROTEM group ($113,142.89 vs. $127,814.77). CONCLUSION: In conclusion implementation of a ROTEM-guided transfusion algorithm resulted in a reduction in intra-operative blood loss, FFP transfusion and a decrease in direct cost during OLT. ROTEM is a useful and safe point of care device in OLT setting.

Why it matters

OpenAlex reports 83 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: Orthotopic liver transplantation (OLT) can be associated with significant bleeding requiring multiple blood product transfusions. Rotational thromboelastometry (ROTEM) is a point-of-care device that has been used to monitor coagulation during OLT. Whether it reduces blood loss/transfusions during OLT remains controversial. MATERIALS AND METHODS: We aim to compare ROTEM with conventional coagulation tests (aPTT, PT, INR, platelet count, fibrinogen) to guide transfusion of platelets, cryoprecipitate, and fresh frozen plasma (FFP) during OLT over 3 years. Thirty-four patients who had transfusions guided by ROTEM were compared to 34 controls who received transfusions guided by conventional coagulation tests (CCT). Intraoperative blood loss, type/ amount of blood products transfused, and direct costs were compared between the two groups. RESULTS: The ROTEM group had significantly less intra-operative blood loss (2.0 vs. 3.0 L, p = 0.04) and fresh frozen plasma (FFP) transfusion (4 units vs. 6.5 units, p = 0.015) compared to the CCT group (2.0L vs. 3.0L, p = 0.04). However, total number of patients transfused cryoprecipitate was increased in ROTEM (n = 25;73%) as compared to CCT (n = 19; 56%), p = 0.033. The direct cost of blood products plus testing was reduced in the ROTEM group ($113,142.89 vs. $127,814.77). CONCLUSION: In conclusion implementation of a ROTEM-guided transfusion algorithm resulted in a reduction in intra-operative blood loss, FFP transfusion and a decrease in direct cost during OLT. ROTEM is a useful and safe point of care device in OLT setting.

Key concepts: Thromboelastometry, Medicine, Cryoprecipitate, Fresh frozen plasma, Blood product, Coagulation testing, Coagulation, Fibrinogen

Related papers

Back to paper searchBrowse research topicsOriginal source
Rotational Thromboelastometry or Conventional Coagulation Tests in Liver Transplantation: Comparing Blood Loss, Transfusions, and Cost — Research Paper | ScholarLens