2014•PubMedRequires access

Non-invasive estimated continuous cardiac output (escCO) during severe sepsis and septic shock resuscitation.

Chairat Permpikul, Thongchai Leelayuthachai

Open publisher page 11 citations

Abstract

BACKGROUND: Cardiac output (CO) is an important hemodynamic parameter during sepsis and septic shock resuscitation. Conventionally, this value is obtained at bedside by the thermodilution technique, which requires a pulmonary artery catheter (PAC). Estimated Continuous Cardiac Output (esCCO, Nihon Kohden, Japan) calculated from pulse-wave transit time (PWTT) was examined here as an alternative. MATERIAL AND METHOD: A prospective study was performed in a 14-bed ICU facility. Patients with severe sepsis and septic shock who had PAC placed were included. Serial thermodilution cardiac outputs (CO(IBT)) and esCCO (COesCCO) were obtained at the beginning of resuscitation (t0), at 48 hours (t48), and at 72 hours (t72). Other parameters from the tested device; namely, estimated continuous cardiac index (esCCI), estimated stroke volume (esSV), and estimated stroke volume index (esSVI), were also achieved. RESULTS: A total of 90-paired readings from ten ICU patients were collected. The overall correlation coefficient (R) between COesCCO and CO(IBT) was 0.76. When focusing on the correlation from each time point, we found R at t0 = 0.65, t48 = 0.74, and t72 = 0.84 (all p < 0.001). Bland and Altman analysis corrected for repeated measures showed a bias of 1.2 liter/min and limits of agreement from -2.8 to +5.2 liter/min. Results also showed fair to poor correlation with other parameters that derived from this device (esCCI, esSV esSVI). CONCLUSION: The estimated continuous cardiac output (esCCO) correlated well with the cardiac output obtained by thermodilution techniques, especially when patients were out of shock.

About this research paper

What this paper is about

BACKGROUND: Cardiac output (CO) is an important hemodynamic parameter during sepsis and septic shock resuscitation. Conventionally, this value is obtained at bedside by the thermodilution technique, which requires a pulmonary artery catheter (PAC). Estimated Continuous Cardiac Output (esCCO, Nihon Kohden, Japan) calculated from pulse-wave transit time (PWTT) was examined here as an alternative. MATERIAL AND METHOD: A prospective study was performed in a 14-bed ICU facility. Patients with severe sepsis and septic shock who had PAC placed were included. Serial thermodilution cardiac outputs (CO(IBT)) and esCCO (COesCCO) were obtained at the beginning of resuscitation (t0), at 48 hours (t48), and at 72 hours (t72). Other parameters from the tested device; namely, estimated continuous cardiac index (esCCI), estimated stroke volume (esSV), and estimated stroke volume index (esSVI), were also achieved. RESULTS: A total of 90-paired readings from ten ICU patients were collected. The overall correlation coefficient (R) between COesCCO and CO(IBT) was 0.76. When focusing on the correlation from each time point, we found R at t0 = 0.65, t48 = 0.74, and t72 = 0.84 (all p < 0.001). Bland and Altman analysis corrected for repeated measures showed a bias of 1.2 liter/min and limits of agreement from -2.8 to +5.2 liter/min. Results also showed fair to poor correlation with other parameters that derived from this device (esCCI, esSV esSVI). CONCLUSION: The estimated continuous cardiac output (esCCO) correlated well with the cardiac output obtained by thermodilution techniques, especially when patients were out of shock.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Cardiac output (CO) is an important hemodynamic parameter during sepsis and septic shock resuscitation. Conventionally, this value is obtained at bedside by the thermodilution technique, which requires a pulmonary artery catheter (PAC). Estimated Continuous Cardiac Output (esCCO, Nihon Kohden, Japan) calculated from pulse-wave transit time (PWTT) was examined here as an alternative. MATERIAL AND METHOD: A prospective study was performed in a 14-bed ICU facility. Patients with severe sepsis and septic shock who had PAC placed were included. Serial thermodilution cardiac outputs (CO(IBT)) and esCCO (COesCCO) were obtained at the beginning of resuscitation (t0), at 48 hours (t48), and at 72 hours (t72). Other parameters from the tested device; namely, estimated continuous cardiac index (esCCI), estimated stroke volume (esSV), and estimated stroke volume index (esSVI), were also achieved. RESULTS: A total of 90-paired readings from ten ICU patients were collected. The overall correlation coefficient (R) between COesCCO and CO(IBT) was 0.76. When focusing on the correlation from each time point, we found R at t0 = 0.65, t48 = 0.74, and t72 = 0.84 (all p < 0.001). Bland and Altman analysis corrected for repeated measures showed a bias of 1.2 liter/min and limits of agreement from -2.8 to +5.2 liter/min. Results also showed fair to poor correlation with other parameters that derived from this device (esCCI, esSV esSVI). CONCLUSION: The estimated continuous cardiac output (esCCO) correlated well with the cardiac output obtained by thermodilution techniques, especially when patients were out of shock.

Key concepts: Medicine, Pulmonary artery catheter, Cardiac output, Septic shock, Resuscitation, Stroke volume, Cardiac index, Sepsis

Related papers

Back to paper searchBrowse research topicsOriginal source
Non-invasive estimated continuous cardiac output (escCO) during severe sepsis and septic shock resuscitation. — Research Paper | ScholarLens