2007Chinese Journal of Critical Care MedicineRequires access

Hemodynamics monitoring—pulse-indicator continuous cardiac output versus pulmonary artery catheter

Huawei Zhang

Open publisher page 0 citations

Abstract

Objective To assess the accuracy of pulse-indicator continuous cardiac output (PiCCO) for the hemodynamics monitoring. Methods 30 critically ill patients with different etiological factors were admitted into intensive care unit. Hemodynamics of each patient was monitored by pulse-indicator continuous cardiac output and pulmonary artery catheter simultaneously. Correlation between the two methods was compared. Results Linear regression analysis revealed the two methods had good correlation [r=0.865 for cardiac output, r=0.879 for cardiac index, r=0.824 for stroke volume, r=0.833 for systemic vascular resistance]. Conclusion PiCCO can provide effectively hemodynamics monitoring for the management of the critical illness.

About this research paper

What this paper is about

Objective To assess the accuracy of pulse-indicator continuous cardiac output (PiCCO) for the hemodynamics monitoring. Methods 30 critically ill patients with different etiological factors were admitted into intensive care unit. Hemodynamics of each patient was monitored by pulse-indicator continuous cardiac output and pulmonary artery catheter simultaneously. Correlation between the two methods was compared. Results Linear regression analysis revealed the two methods had good correlation [r=0.865 for cardiac output, r=0.879 for cardiac index, r=0.824 for stroke volume, r=0.833 for systemic vascular resistance]. Conclusion PiCCO can provide effectively hemodynamics monitoring for the management of the critical illness.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To assess the accuracy of pulse-indicator continuous cardiac output (PiCCO) for the hemodynamics monitoring. Methods 30 critically ill patients with different etiological factors were admitted into intensive care unit. Hemodynamics of each patient was monitored by pulse-indicator continuous cardiac output and pulmonary artery catheter simultaneously. Correlation between the two methods was compared. Results Linear regression analysis revealed the two methods had good correlation [r=0.865 for cardiac output, r=0.879 for cardiac index, r=0.824 for stroke volume, r=0.833 for systemic vascular resistance]. Conclusion PiCCO can provide effectively hemodynamics monitoring for the management of the critical illness.

Key concepts: Pulmonary artery catheter, Medicine, Cardiac output, Hemodynamics, Cardiac index, Pulmonary artery, Stroke volume, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Hemodynamics monitoring—pulse-indicator continuous cardiac output versus pulmonary artery catheter — Research Paper | ScholarLens