Recent advances in building envelope systems and fenestration have resulted in improved building envelopes, reducing both the air leakage and the heat transfer with the surroundings. At the same time, the power consumption of the heating, ventilation, and air-conditioning systems is reduced due to the improvement in their energy efficiency. This leaves plug and miscellaneous loads as one of the main contributors to the overall energy consumption of buildings, accounting for up to 50% of the building's total energy consumption (NBI 2012 New Buildings Institute (NBI). 2012. Plug load best practices guide: Managing your office equipment plug load. https://new-buildings.org/resource/plug-load-best-practices-guide/ (accessed 04/04/2017) [Google Scholar]). As a result of this, it is important to accurately assess the energy consumed by plug loads as overestimation can result in oversized HVAC systems increasing capital and operating cost while undersized systems result in thermal comfort problems for occupants. The ASHRAE Fundamental Handbook heat gain tables were last updated in 2009. Since then, equipment's power management capabilities improved tremendously and many new types of office equipment were introduced. ASHRAE, therefore, funded research project RP-1742 to update heat gain tables. The current article outlines the experimental methodology used in RP-1742 to measure heat gain values for different office equipment. The peak heat gain values for various office equipment are listed in different tables in the result section of the article and will be included in the 2017 ASHRAE Fundamentals Handbook.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Recent advances in building envelope systems and fenestration have resulted in improved building envelopes, reducing both the air leakage and the heat transfer with the surroundings. At the same time, the power consumption of the heating, ventilation, and air-conditioning systems is reduced due to the improvement in their energy efficiency. This leaves plug and miscellaneous loads as one of the main contributors to the overall energy consumption of buildings, accounting for up to 50% of the building's total energy consumption (NBI 2012 New Buildings Institute (NBI). 2012. Plug load best practices guide: Managing your office equipment plug load. https://new-buildings.org/resource/plug-load-best-practices-guide/ (accessed 04/04/2017) [Google Scholar]). As a result of this, it is important to accurately assess the energy consumed by plug loads as overestimation can result in oversized HVAC systems increasing capital and operating cost while undersized systems result in thermal comfort problems for occupants. The ASHRAE Fundamental Handbook heat gain tables were last updated in 2009. Since then, equipment's power management capabilities improved tremendously and many new types of office equipment were introduced. ASHRAE, therefore, funded research project RP-1742 to update heat gain tables. The current article outlines the experimental methodology used in RP-1742 to measure heat gain values for different office equipment. The peak heat gain values for various office equipment are listed in different tables in the result section of the article and will be included in the 2017 ASHRAE Fundamentals Handbook.
Key concepts: ASHRAE 90.1, HVAC, Building envelope, Engineering, Air conditioning, Cooling load, Energy consumption, Efficient energy use