2017Hyomen KagakuOpen access

Approach to Highly Sensitive XAFS by Means of Bent Crystal Laue Analyzers

Yuki Wakisaka, Yuya Iwasaki, Hiromitsu Uehara, Shingo Mukai, Daiki Kido, Satoru Takakusagi, Yohei Uemura, Takahiro Wada, Qiuyi Yuan, Oki Sekizawa, Tomoya Uruga, Yasuhiro Iwasawa, Kiyotaka Asakura

Open full text 4 citations

Abstract

A log-spirally bent crystal Laue analyzer has been investigated and developed for highly sensitive in situ surface X-ray absorption fine structure (XAFS) measurement. Both calculations and experiments were conducted to obtain its intensity distributions on the different positions of the analyzer. A home-made log-spirally bent crystal Laue analyzer was made and evaluated. It was revealed that higher XAFS signals were obtained with the home-made analyzer than with the commercial one.

Open-access reader

About this research paper

What this paper is about

A log-spirally bent crystal Laue analyzer has been investigated and developed for highly sensitive in situ surface X-ray absorption fine structure (XAFS) measurement. Both calculations and experiments were conducted to obtain its intensity distributions on the different positions of the analyzer. A home-made log-spirally bent crystal Laue analyzer was made and evaluated. It was revealed that higher XAFS signals were obtained with the home-made analyzer than with the commercial one.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A log-spirally bent crystal Laue analyzer has been investigated and developed for highly sensitive in situ surface X-ray absorption fine structure (XAFS) measurement. Both calculations and experiments were conducted to obtain its intensity distributions on the different positions of the analyzer. A home-made log-spirally bent crystal Laue analyzer was made and evaluated. It was revealed that higher XAFS signals were obtained with the home-made analyzer than with the commercial one.

Key concepts: X-ray absorption fine structure, Bent molecular geometry, Spectrum analyzer, Crystal (programming language), Materials science, Absorption (acoustics), Optics, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Approach to Highly Sensitive XAFS by Means of Bent Crystal Laue Analyzers — Research Paper | ScholarLens