2011•International Journal of Chemical SciencesRequires access

RP-HPLC Method for Simultaneous Estimation of Paracetamol and Drotaverine Hydrochloride in Pharmaceutical Formulations

G. Tulja Rani, Dannana Gowri Sankar, P. Kadgapathi, NuggehallyR Srinivas, Bonthu Satyanarayana

Open publisher page 0 citations

Abstract

A simple, sensitive and precise reverse phase high performance liquid chromatographic method (RP-HPLC) has been developed and validated for the simultaneous estimation of paracetamol and drotaverine hydrochloride in both : bulk drug samples and formulation. The method was carried out on a phenomenex Luna C-18 (250 mm × i.d -4.6 mm, particle size 5 µm) column with a mobile phase consisting of methanol : water (pH adjusted to 3.34 with 0. 1% ortho-phosphoric acid) in the ratio of 52 : 48 (v/v). The flow rate was optimized at 1 mL/min and effluent was monitored at detection wavelength of 246 nm. The total chromatographic run time was 10 minutes and the retention time of paracetamol and drotaverine hydrochloride was 3.18 min and 5.07 min, respectively. The method was proved to be accurate and precise at linearity range of 2-36 µg/mL for paracetamol and 1-60 µg/mL for drotaverine hydrochloride with a correlation coefficient (r2 ) 0.999 and 0.9991, respectively. The method is highly reproducible with recoveries ranging from 99.93-100.2% and 99.90-100.16% for paracetamol and drotaverine hydrochloride, respectively. The method was validated for accuracy, precision, robustness, detection and quantification limits as per ICH guidelines. The intra- and inter- day precision and accuracy values were found to be within the limits. Due to its simplicity, accuracy and economical value, the proposed method can be used for routine quality analysis of these drugs in bulk and combined dosage form.

About this research paper

What this paper is about

A simple, sensitive and precise reverse phase high performance liquid chromatographic method (RP-HPLC) has been developed and validated for the simultaneous estimation of paracetamol and drotaverine hydrochloride in both : bulk drug samples and formulation. The method was carried out on a phenomenex Luna C-18 (250 mm × i.d -4.6 mm, particle size 5 µm) column with a mobile phase consisting of methanol : water (pH adjusted to 3.34 with 0. 1% ortho-phosphoric acid) in the ratio of 52 : 48 (v/v). The flow rate was optimized at 1 mL/min and effluent was monitored at detection wavelength of 246 nm. The total chromatographic run time was 10 minutes and the retention time of paracetamol and drotaverine hydrochloride was 3.18 min and 5.07 min, respectively. The method was proved to be accurate and precise at linearity range of 2-36 µg/mL for paracetamol and 1-60 µg/mL for drotaverine hydrochloride with a correlation coefficient (r2 ) 0.999 and 0.9991, respectively. The method is highly reproducible with recoveries ranging from 99.93-100.2% and 99.90-100.16% for paracetamol and drotaverine hydrochloride, respectively. The method was validated for accuracy, precision, robustness, detection and quantification limits as per ICH guidelines. The intra- and inter- day precision and accuracy values were found to be within the limits. Due to its simplicity, accuracy and economical value, the proposed method can be used for routine quality analysis of these drugs in bulk and combined dosage form.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, sensitive and precise reverse phase high performance liquid chromatographic method (RP-HPLC) has been developed and validated for the simultaneous estimation of paracetamol and drotaverine hydrochloride in both : bulk drug samples and formulation. The method was carried out on a phenomenex Luna C-18 (250 mm × i.d -4.6 mm, particle size 5 µm) column with a mobile phase consisting of methanol : water (pH adjusted to 3.34 with 0. 1% ortho-phosphoric acid) in the ratio of 52 : 48 (v/v). The flow rate was optimized at 1 mL/min and effluent was monitored at detection wavelength of 246 nm. The total chromatographic run time was 10 minutes and the retention time of paracetamol and drotaverine hydrochloride was 3.18 min and 5.07 min, respectively. The method was proved to be accurate and precise at linearity range of 2-36 µg/mL for paracetamol and 1-60 µg/mL for drotaverine hydrochloride with a correlation coefficient (r2 ) 0.999 and 0.9991, respectively. The method is highly reproducible with recoveries ranging from 99.93-100.2% and 99.90-100.16% for paracetamol and drotaverine hydrochloride, respectively. The method was validated for accuracy, precision, robustness, detection and quantification limits as per ICH guidelines. The intra- and inter- day precision and accuracy values were found to be within the limits. Due to its simplicity, accuracy and economical value, the proposed method can be used for routine quality analysis of these drugs in bulk and combined dosage form.

Key concepts: Chromatography, Correlation coefficient, Chemistry, Phosphoric acid, Dosage form, Detection limit, Particle size, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
RP-HPLC Method for Simultaneous Estimation of Paracetamol and Drotaverine Hydrochloride in Pharmaceutical Formulations — Research Paper | ScholarLens