A simple and precise high performance liquid chromatographic method has been developed and validated for the simultaneous determination of drotaverine hydrochloride, domperidone and paracetamol in a binary tablet formulation containing drotaverine hydrochloride-paracetamol and/or domperidone-paracetamol. Chromatography was carried out at 25°C on a 4.6mmA150mm, 5I¼m Symmetry shield RP 18 column with the isocratic mobile phase of 0.02M aqueous potassium dihydrogen phosphate buffer (pH 7.5) and acetonitrile (40:60, v/v) at a flow rate of 0.5 ml/min. Drotaverine hydrochloride, domperidone and paracetamol were separated in less than 10 min with good resolution and minimal tailing, without interference of excipients. The method was validated according to ICH guidelines and the acceptance criteria for accuracy, precision, linearity, specificity and system suitability were met in all cases. The method was linear in the range of 192â448I¼g/ml for drotaverine hydrochloride, 24â56I¼g/ml for domperidone and 12â28I¼g/ml for paracetamol.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple and precise high performance liquid chromatographic method has been developed and validated for the simultaneous determination of drotaverine hydrochloride, domperidone and paracetamol in a binary tablet formulation containing drotaverine hydrochloride-paracetamol and/or domperidone-paracetamol. Chromatography was carried out at 25°C on a 4.6mmA150mm, 5I¼m Symmetry shield RP 18 column with the isocratic mobile phase of 0.02M aqueous potassium dihydrogen phosphate buffer (pH 7.5) and acetonitrile (40:60, v/v) at a flow rate of 0.5 ml/min. Drotaverine hydrochloride, domperidone and paracetamol were separated in less than 10 min with good resolution and minimal tailing, without interference of excipients. The method was validated according to ICH guidelines and the acceptance criteria for accuracy, precision, linearity, specificity and system suitability were met in all cases. The method was linear in the range of 192â448I¼g/ml for drotaverine hydrochloride, 24â56I¼g/ml for domperidone and 12â28I¼g/ml for paracetamol.
Key concepts: Domperidone, Chromatography, Chemistry, High-performance liquid chromatography, Dosage form, Medicine, Dopamine, Endocrinology