Study on measurement method of shield continuity for shielded cable with drain wire

Hongje Jang, Tae-Seung Song, Tae-Hyeob Song

Open publisher page 0 citations

Abstract

Industry cable is used with hundreds of meters or several kilometers. If there is any problem in cable, kind of disconnection or defect, it is difficult to detect any defective part on entire cable. To resolve this inconvenience, the cable measurement method of detecting defects or damages on cable by moving only small testing area was studied. The proposed method needs an input signal with 30 MHz CW from signal generator, small loop probe and housing box with inside shielded pipe. It will continuously detect the leakage signal in defected or damaged part of the cable. This paper shows the effective result to find a problematic point on cable.

About this research paper

What this paper is about

Industry cable is used with hundreds of meters or several kilometers. If there is any problem in cable, kind of disconnection or defect, it is difficult to detect any defective part on entire cable. To resolve this inconvenience, the cable measurement method of detecting defects or damages on cable by moving only small testing area was studied. The proposed method needs an input signal with 30 MHz CW from signal generator, small loop probe and housing box with inside shielded pipe. It will continuously detect the leakage signal in defected or damaged part of the cable. This paper shows the effective result to find a problematic point on cable.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Industry cable is used with hundreds of meters or several kilometers. If there is any problem in cable, kind of disconnection or defect, it is difficult to detect any defective part on entire cable. To resolve this inconvenience, the cable measurement method of detecting defects or damages on cable by moving only small testing area was studied. The proposed method needs an input signal with 30 MHz CW from signal generator, small loop probe and housing box with inside shielded pipe. It will continuously detect the leakage signal in defected or damaged part of the cable. This paper shows the effective result to find a problematic point on cable.

Key concepts: Shielded cable, Shield, SIGNAL (programming language), Direct-buried cable, Electromagnetic shielding, Cable harness, Electrical engineering, Leakage (economics)