2017Energy ProcediaOpen access

Heat source shifting in buildings supplied by district heating and exhaust air heat pump

Johan Kensby, Anders Trüschel, Jan-Olof Dalenbäck

Open full text 17 citations

Abstract

The heat supply for Swedish multi-family residential buildings is becoming more complex, and today it is fairly common to combine district heating with a second heat source. The most common heat source to combine with district heating in Sweden is an exhaust air heat pump. On average, the exhaust air heat pump covers 31% of the yearly heat load and is given full load priority. There is a missed potential in cost and CO2 savings when one heat source is given full load priority, since marginal production costs and CO2 emissions constantly vary in both the electrical grid and the district heating system. The aim of this study is to evaluate how buildings with several heat sources should be operated using hourly energy prices. Hourly heat and electricity prices for Gothenburg have been established for two years based on the marginal costs of heat and electricity generation. These prices have been used to evaluate the most common combinations of heat sources. Results show that the most common combination with an exhaust air heat pump with full load priority does not lower costs compared to the reference case with only district heating. However, having a control system that allows heat source shifting and gives load priority to the heat source with the lowest cost each hour can greatly reduce the heating cost, and systems with larger heat pumps show even greater potential for heat source shifting.

Open-access reader

About this research paper

What this paper is about

The heat supply for Swedish multi-family residential buildings is becoming more complex, and today it is fairly common to combine district heating with a second heat source. The most common heat source to combine with district heating in Sweden is an exhaust air heat pump. On average, the exhaust air heat pump covers 31% of the yearly heat load and is given full load priority. There is a missed potential in cost and CO2 savings when one heat source is given full load priority, since marginal production costs and CO2 emissions constantly vary in both the electrical grid and the district heating system. The aim of this study is to evaluate how buildings with several heat sources should be operated using hourly energy prices. Hourly heat and electricity prices for Gothenburg have been established for two years based on the marginal costs of heat and electricity generation. These prices have been used to evaluate the most common combinations of heat sources. Results show that the most common combination with an exhaust air heat pump with full load priority does not lower costs compared to the reference case with only district heating. However, having a control system that allows heat source shifting and gives load priority to the heat source with the lowest cost each hour can greatly reduce the heating cost, and systems with larger heat pumps show even greater potential for heat source shifting.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The heat supply for Swedish multi-family residential buildings is becoming more complex, and today it is fairly common to combine district heating with a second heat source. The most common heat source to combine with district heating in Sweden is an exhaust air heat pump. On average, the exhaust air heat pump covers 31% of the yearly heat load and is given full load priority. There is a missed potential in cost and CO2 savings when one heat source is given full load priority, since marginal production costs and CO2 emissions constantly vary in both the electrical grid and the district heating system. The aim of this study is to evaluate how buildings with several heat sources should be operated using hourly energy prices. Hourly heat and electricity prices for Gothenburg have been established for two years based on the marginal costs of heat and electricity generation. These prices have been used to evaluate the most common combinations of heat sources. Results show that the most common combination with an exhaust air heat pump with full load priority does not lower costs compared to the reference case with only district heating. However, having a control system that allows heat source shifting and gives load priority to the heat source with the lowest cost each hour can greatly reduce the heating cost, and systems with larger heat pumps show even greater potential for heat source shifting.

Key concepts: Heat pump, Air source heat pumps, Hybrid heat, Storage heater, Renewable heat, Environmental science, Coefficient of performance, Electricity

Related papers

Back to paper searchBrowse research topicsOriginal source
Heat source shifting in buildings supplied by district heating and exhaust air heat pump — Research Paper | ScholarLens