Research on a New District Heating Method Combined with Hot Water Driven Ground Source Absorption Heat Pump

Zhang Qunli, Cao Mingkai, Zhang Qiuyue, DI Hongfa

Open full text 11 citations

Abstract

A new district heating method combined with hot water driven ground source absorption heat pump to extract shallow geothermal was put forward, and the district heating system provides hot water for the driven heat source of the absorption heat pump. By the primary energy efficiency and economical analysis method, research results show that compared with the conventional district heating system, the heating capacity of the new district heating system can be greatly improved and the heating costs can be largely reduced without expanding the capacity of district heating system and increasing other energy consumption. Also, compared with electric-driven ground source heat pump heating system, the new district heating system utilized high temperature water as the driven heating resource to replace the high grade electricity, which can improve significantly the energy utilization efficiency and decrease sharply the power consumption. Compared with electric-driven ground source heat pump heating system on the same heat quantity condition, the new district heating system has the advantage of lower first energy consumption and smaller size of underground heat exchanger and the smaller heat extraction during winter period which was conducive to achieve winter and summer heat balance.

About this research paper

What this paper is about

A new district heating method combined with hot water driven ground source absorption heat pump to extract shallow geothermal was put forward, and the district heating system provides hot water for the driven heat source of the absorption heat pump. By the primary energy efficiency and economical analysis method, research results show that compared with the conventional district heating system, the heating capacity of the new district heating system can be greatly improved and the heating costs can be largely reduced without expanding the capacity of district heating system and increasing other energy consumption. Also, compared with electric-driven ground source heat pump heating system, the new district heating system utilized high temperature water as the driven heating resource to replace the high grade electricity, which can improve significantly the energy utilization efficiency and decrease sharply the power consumption. Compared with electric-driven ground source heat pump heating system on the same heat quantity condition, the new district heating system has the advantage of lower first energy consumption and smaller size of underground heat exchanger and the smaller heat extraction during winter period which was conducive to achieve winter and summer heat balance.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new district heating method combined with hot water driven ground source absorption heat pump to extract shallow geothermal was put forward, and the district heating system provides hot water for the driven heat source of the absorption heat pump. By the primary energy efficiency and economical analysis method, research results show that compared with the conventional district heating system, the heating capacity of the new district heating system can be greatly improved and the heating costs can be largely reduced without expanding the capacity of district heating system and increasing other energy consumption. Also, compared with electric-driven ground source heat pump heating system, the new district heating system utilized high temperature water as the driven heating resource to replace the high grade electricity, which can improve significantly the energy utilization efficiency and decrease sharply the power consumption. Compared with electric-driven ground source heat pump heating system on the same heat quantity condition, the new district heating system has the advantage of lower first energy consumption and smaller size of underground heat exchanger and the smaller heat extraction during winter period which was conducive to achieve winter and summer heat balance.

Key concepts: Heat pump, Absorption heat pump, Renewable heat, Heating system, Hybrid heat, Air source heat pumps, Electric heating, Storage heater

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on a New District Heating Method Combined with Hot Water Driven Ground Source Absorption Heat Pump — Research Paper | ScholarLens