2012•Unpublished venueRequires access

Development and Validation of a RP-HPLC Method for Simultaneous Estimation of Diacerein and Aceclofenac in Pharmaceutical Dosage Form

Narendra Kumar Nyola, Govinda Samy Jeyabalan, Naveen Kalra, Gazala Parveen, Suresh Choudhary

Open publisher page 7 citations

Abstract

A new simple, accurate, precise and reproducible RP-HPLC method has been developed for the simultaneous estimation of Diacerein and Aceclofenac in pharmaceutical dosage form using C18 column (Phenomenex, 250 x 4.6 mm, 5 μm) in isocratic mode. The mobile phase consisted of Acetonitrile and Water in the ratio of 55:45 (v/v). The detection wavelength was carried out at 271 nm. The method was linear over the concentration range for Aceclofenac 50-75 μg/ml and for Diacerein 100-150 μg/ml. The recoveries of Aceclofenac and Diacerein were found to be in the range of 99.23-100.39% and 99.45-100.56% respectively. The validation of method was carried out utilizing ICH-guidelines. The described HPLC method was successfully employed for the analysis of pharmaceutical formulations containing combined dosage form.

About this research paper

What this paper is about

A new simple, accurate, precise and reproducible RP-HPLC method has been developed for the simultaneous estimation of Diacerein and Aceclofenac in pharmaceutical dosage form using C18 column (Phenomenex, 250 x 4.6 mm, 5 μm) in isocratic mode. The mobile phase consisted of Acetonitrile and Water in the ratio of 55:45 (v/v). The detection wavelength was carried out at 271 nm. The method was linear over the concentration range for Aceclofenac 50-75 μg/ml and for Diacerein 100-150 μg/ml. The recoveries of Aceclofenac and Diacerein were found to be in the range of 99.23-100.39% and 99.45-100.56% respectively. The validation of method was carried out utilizing ICH-guidelines. The described HPLC method was successfully employed for the analysis of pharmaceutical formulations containing combined dosage form.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new simple, accurate, precise and reproducible RP-HPLC method has been developed for the simultaneous estimation of Diacerein and Aceclofenac in pharmaceutical dosage form using C18 column (Phenomenex, 250 x 4.6 mm, 5 μm) in isocratic mode. The mobile phase consisted of Acetonitrile and Water in the ratio of 55:45 (v/v). The detection wavelength was carried out at 271 nm. The method was linear over the concentration range for Aceclofenac 50-75 μg/ml and for Diacerein 100-150 μg/ml. The recoveries of Aceclofenac and Diacerein were found to be in the range of 99.23-100.39% and 99.45-100.56% respectively. The validation of method was carried out utilizing ICH-guidelines. The described HPLC method was successfully employed for the analysis of pharmaceutical formulations containing combined dosage form.

Key concepts: Aceclofenac, Dosage form, Chromatography, High-performance liquid chromatography, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and Validation of a RP-HPLC Method for Simultaneous Estimation of Diacerein and Aceclofenac in Pharmaceutical Dosage Form — Research Paper | ScholarLens