2010•Research Journal of Pharmacy and TechnologyRequires access

HPTLC Method for the Simultaneous Estimation of Aceclofenac and Diacerein in Tablets Dosage Forms

R Siva Kumar, N Srisutherson, P. Kumar Nallasivan, P. Arulraj, R. Venkatnarayanan

Open publisher page 2 citations

Abstract

A new simple, accurate, precise HPTLC method has been developed for the simultaneous estimation of Aceclofenac and Diacerein in tablets formulation. In this method standard and sample solutions of Aceclofenac and Diacerein were applied on pre-coated silica gel G 60 f 254 TLC plate, and developed using chloroform: methanol (8: 2 v/v), as mobile phase. The drugs on plate were scanned at 256nm. The dynamic linearity range was 10–50 μg/spot for aceclofenac and 5–25 μg/spot for Diacerein. The method was validated for precision, accuracy and reproducibility.

About this research paper

What this paper is about

A new simple, accurate, precise HPTLC method has been developed for the simultaneous estimation of Aceclofenac and Diacerein in tablets formulation. In this method standard and sample solutions of Aceclofenac and Diacerein were applied on pre-coated silica gel G 60 f 254 TLC plate, and developed using chloroform: methanol (8: 2 v/v), as mobile phase. The drugs on plate were scanned at 256nm. The dynamic linearity range was 10–50 μg/spot for aceclofenac and 5–25 μg/spot for Diacerein. The method was validated for precision, accuracy and reproducibility.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new simple, accurate, precise HPTLC method has been developed for the simultaneous estimation of Aceclofenac and Diacerein in tablets formulation. In this method standard and sample solutions of Aceclofenac and Diacerein were applied on pre-coated silica gel G 60 f 254 TLC plate, and developed using chloroform: methanol (8: 2 v/v), as mobile phase. The drugs on plate were scanned at 256nm. The dynamic linearity range was 10–50 μg/spot for aceclofenac and 5–25 μg/spot for Diacerein. The method was validated for precision, accuracy and reproducibility.

Key concepts: Aceclofenac, Dosage form, Reproducibility, Chromatography, Mathematics, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
HPTLC Method for the Simultaneous Estimation of Aceclofenac and Diacerein in Tablets Dosage Forms — Research Paper | ScholarLens