2017Journal of Clinical and Experimental DentistryOpen access

Evaluation of ex vivo effectiveness of commercial desensitizing dentifrices

Hanny Reis Mockdeci, Hudson Polonini, Isabella Bispo Diaz T Martins, AP Granato, Nádia Rezende Barbosa Raposo, MG Chaves

Open full text 20 citations

Abstract

Background: Dentin hypersensitivity is a short, severe pain with fast onset.Therapy aims to either prevent or decrease neural transmission or physically occlude the dentinal tubules.This study aimed to evaluate the effectiveness of commercial desensitizing dentifrice by means of an ex vivo method.Material and Methods: Samples (n=8 lower human premolars for each group) were randomly allocated into: G1brushing with Colgate®Sensitive Pro-Relief; G2-brushing with Sensodyne®Rapid Relief; G3-brushing with Sensodyne®Repair & Protect; and G4-brushing with Colgate®Maximum Cavity Protection.The test bodies were submitted to simulated toothbrushing and dentifrices were analyzed regarding their hydrodynamic size, polydispersity index (PI) and zeta potential.Specimens were evaluated using: scanning electron microscopy (SEM); spectroscopy energy dispersive X-ray (EDS); and profilometry.A qualitative analysis of the photomicrographs and topographies was performed.Results: The dentifrices showed statistical similar physical and chemical characteristics.They also demonstrated obliteration of dentinal tubules when micrographs were observed.Regarding the chemical elements present in the dentin samples, there was a statistically significant difference between the control and experimental surfaces in the four groups.Conclusions: Joint data analysis shows that the desensitizing dentifrice showed better results with regards to the obliteration of dentinal tubules compared to positive and negative controls.

Open-access reader

About this research paper

What this paper is about

Background: Dentin hypersensitivity is a short, severe pain with fast onset.Therapy aims to either prevent or decrease neural transmission or physically occlude the dentinal tubules.This study aimed to evaluate the effectiveness of commercial desensitizing dentifrice by means of an ex vivo method.Material and Methods: Samples (n=8 lower human premolars for each group) were randomly allocated into: G1brushing with Colgate®Sensitive Pro-Relief; G2-brushing with Sensodyne®Rapid Relief; G3-brushing with Sensodyne®Repair & Protect; and G4-brushing with Colgate®Maximum Cavity Protection.The test bodies were submitted to simulated toothbrushing and dentifrices were analyzed regarding their hydrodynamic size, polydispersity index (PI) and zeta potential.Specimens were evaluated using: scanning electron microscopy (SEM); spectroscopy energy dispersive X-ray (EDS); and profilometry.A qualitative analysis of the photomicrographs and topographies was performed.Results: The dentifrices showed statistical similar physical and chemical characteristics.They also demonstrated obliteration of dentinal tubules when micrographs were observed.Regarding the chemical elements present in the dentin samples, there was a statistically significant difference between the control and experimental surfaces in the four groups.Conclusions: Joint data analysis shows that the desensitizing dentifrice showed better results with regards to the obliteration of dentinal tubules compared to positive and negative controls.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: Dentin hypersensitivity is a short, severe pain with fast onset.Therapy aims to either prevent or decrease neural transmission or physically occlude the dentinal tubules.This study aimed to evaluate the effectiveness of commercial desensitizing dentifrice by means of an ex vivo method.Material and Methods: Samples (n=8 lower human premolars for each group) were randomly allocated into: G1brushing with Colgate®Sensitive Pro-Relief; G2-brushing with Sensodyne®Rapid Relief; G3-brushing with Sensodyne®Repair & Protect; and G4-brushing with Colgate®Maximum Cavity Protection.The test bodies were submitted to simulated toothbrushing and dentifrices were analyzed regarding their hydrodynamic size, polydispersity index (PI) and zeta potential.Specimens were evaluated using: scanning electron microscopy (SEM); spectroscopy energy dispersive X-ray (EDS); and profilometry.A qualitative analysis of the photomicrographs and topographies was performed.Results: The dentifrices showed statistical similar physical and chemical characteristics.They also demonstrated obliteration of dentinal tubules when micrographs were observed.Regarding the chemical elements present in the dentin samples, there was a statistically significant difference between the control and experimental surfaces in the four groups.Conclusions: Joint data analysis shows that the desensitizing dentifrice showed better results with regards to the obliteration of dentinal tubules compared to positive and negative controls.

Key concepts: Dentifrice, Dentinal Tubule, Dentin hypersensitivity, Dentistry, Dentin, Ex vivo, Dentine hypersensitivity, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of ex vivo effectiveness of commercial desensitizing dentifrices — Research Paper | ScholarLens