2010Zhonghua miniao waike zazhiRequires access

64-slice spiral CT perfusion imaging in the single renal functional assessment for hydronephrotic kidney

Yunhua Wang, Hou Wei-wei, Ruihong Liu, HE Jian-jun, Zhi Ke

Open publisher page 0 citations

Abstract

Objective To evaluate the value of MSCT perfusion imaging in assessment of singlerenal function of hydronephrotic kidney.Methods 64-slice spiral CT perfusion was performed in 36 obstructive nephrohydrosis patients whose split renal glomerular filtration rate(GFR) was measured by SPECT renal dynamic imaging. ①The perfusion parameters of the renal cortex and renal medulla of the hydronephrotic kidney were compared with the normal kidney studied by contrast group. ②The 72 kidneys were divided into normal renal function, mild and severe renal impairment groups according to renal function. Differences between the groups respect to all the mean perfusion parameters of the renal cortex and renal medulla were assesses by ANOVA. ③Using Pearsons correlation test, the correlations between all the mean perfusion parameters of the renal cortex and renal medulla and renal GFR were examined.Results ① The time-density curves of bilateral normal renal cortex and medulla were not symmetric. The mean BF, BV, PS, PBV of renal cortex were (203. 2±44.9)ml·100 ml~(-1)·min~(-1), (27.6±3.9)ml/100 ml, (30.7±6.5)ml·100 ml~(-1)· min~(-1), (46.5±10. 9)ml/100 ml; and the mean BF, BV, PS, PBV of renal medulla were (99.9±24.1)ml·100 ml~(-1)·min~(-1) ,(18. 3±4.3)ml/100 ml, (51.8±12.1)ml · 100 ml~(-1)· min~(-1) , (21.3±3.0)ml/100 ml. The mean perfusion parameters of the cortex and medulla of obstructed kidney were lower compared to that of normal kidney. ②There were significant differences of all the perfusion parameters of the renal cortex and me-dulla between 3 groups (P<0. 05). ③The perfusion parameters of the renal cortex and medulla had positive linear correlation with GFR. The best correlation was the blood flow of the cortex of kidney. The correlation coefficient r=0.852. Conclusions 64-slice spiral CT perfusion imaging can quantita-tively evaluate the haemodynamic condition and functional lesion of the kidney, classify the impaired kidney function. The perfusion parameters of the renal cortex and medulla had positive linear correlation with GFR. Key words: Tomgraphy;  X-ray computed;  Hydronephrosis

About this research paper

What this paper is about

Objective To evaluate the value of MSCT perfusion imaging in assessment of singlerenal function of hydronephrotic kidney.Methods 64-slice spiral CT perfusion was performed in 36 obstructive nephrohydrosis patients whose split renal glomerular filtration rate(GFR) was measured by SPECT renal dynamic imaging. ①The perfusion parameters of the renal cortex and renal medulla of the hydronephrotic kidney were compared with the normal kidney studied by contrast group. ②The 72 kidneys were divided into normal renal function, mild and severe renal impairment groups according to renal function. Differences between the groups respect to all the mean perfusion parameters of the renal cortex and renal medulla were assesses by ANOVA. ③Using Pearsons correlation test, the correlations between all the mean perfusion parameters of the renal cortex and renal medulla and renal GFR were examined.Results ① The time-density curves of bilateral normal renal cortex and medulla were not symmetric. The mean BF, BV, PS, PBV of renal cortex were (203. 2±44.9)ml·100 ml~(-1)·min~(-1), (27.6±3.9)ml/100 ml, (30.7±6.5)ml·100 ml~(-1)· min~(-1), (46.5±10. 9)ml/100 ml; and the mean BF, BV, PS, PBV of renal medulla were (99.9±24.1)ml·100 ml~(-1)·min~(-1) ,(18. 3±4.3)ml/100 ml, (51.8±12.1)ml · 100 ml~(-1)· min~(-1) , (21.3±3.0)ml/100 ml. The mean perfusion parameters of the cortex and medulla of obstructed kidney were lower compared to that of normal kidney. ②There were significant differences of all the perfusion parameters of the renal cortex and me-dulla between 3 groups (P<0. 05). ③The perfusion parameters of the renal cortex and medulla had positive linear correlation with GFR. The best correlation was the blood flow of the cortex of kidney. The correlation coefficient r=0.852. Conclusions 64-slice spiral CT perfusion imaging can quantita-tively evaluate the haemodynamic condition and functional lesion of the kidney, classify the impaired kidney function. The perfusion parameters of the renal cortex and medulla had positive linear correlation with GFR. Key words: Tomgraphy;  X-ray computed;  Hydronephrosis

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the value of MSCT perfusion imaging in assessment of singlerenal function of hydronephrotic kidney.Methods 64-slice spiral CT perfusion was performed in 36 obstructive nephrohydrosis patients whose split renal glomerular filtration rate(GFR) was measured by SPECT renal dynamic imaging. ①The perfusion parameters of the renal cortex and renal medulla of the hydronephrotic kidney were compared with the normal kidney studied by contrast group. ②The 72 kidneys were divided into normal renal function, mild and severe renal impairment groups according to renal function. Differences between the groups respect to all the mean perfusion parameters of the renal cortex and renal medulla were assesses by ANOVA. ③Using Pearsons correlation test, the correlations between all the mean perfusion parameters of the renal cortex and renal medulla and renal GFR were examined.Results ① The time-density curves of bilateral normal renal cortex and medulla were not symmetric. The mean BF, BV, PS, PBV of renal cortex were (203. 2±44.9)ml·100 ml~(-1)·min~(-1), (27.6±3.9)ml/100 ml, (30.7±6.5)ml·100 ml~(-1)· min~(-1), (46.5±10. 9)ml/100 ml; and the mean BF, BV, PS, PBV of renal medulla were (99.9±24.1)ml·100 ml~(-1)·min~(-1) ,(18. 3±4.3)ml/100 ml, (51.8±12.1)ml · 100 ml~(-1)· min~(-1) , (21.3±3.0)ml/100 ml. The mean perfusion parameters of the cortex and medulla of obstructed kidney were lower compared to that of normal kidney. ②There were significant differences of all the perfusion parameters of the renal cortex and me-dulla between 3 groups (P<0. 05). ③The perfusion parameters of the renal cortex and medulla had positive linear correlation with GFR. The best correlation was the blood flow of the cortex of kidney. The correlation coefficient r=0.852. Conclusions 64-slice spiral CT perfusion imaging can quantita-tively evaluate the haemodynamic condition and functional lesion of the kidney, classify the impaired kidney function. The perfusion parameters of the renal cortex and medulla had positive linear correlation with GFR. Key words: Tomgraphy;  X-ray computed;  Hydronephrosis

Key concepts: Perfusion, Renal medulla, Kidney, Renal cortex, Renal function, Medulla, Medicine, Cortex (anatomy)

Related papers

Back to paper searchBrowse research topicsOriginal source
64-slice spiral CT perfusion imaging in the single renal functional assessment for hydronephrotic kidney — Research Paper | ScholarLens