1996Journal of Architecture and Planning (Transactions of AIJ)Open access

STUDY ON GALVANIC CORROSION AND ITS PREVENTION IN BUILDING PIPING SYSTEM

Toshihiro Yamate, Tatsuya Yoshida, Katuji TUZUKI, Satoru Kaneko

Open full text 2 citations

Abstract

The purpose of this study is to make a guide for the galvanic corrosion prevention in the building piping system. Water loopingtests were performed for 1 year. The galvanic corrosion behavior of the some piping materials were evaluated with a monitoring the corrosion potentials, the galvanic current and the corrosion appearances of the specimens. The main results are followings; 1) The galvanic current tends to decrease with time. An order of the level of the galvanic current is as following. (Higher) A1>Zn/Fe>Fe>brass>Cu and gunmetal (Lower). 2) In the case of the galvanic couple with Al as anode, Al severely corroded in hot water loop test. 3) An insulation between the anode and the cathode, and thier distance for the galvanic corrosion prevention were understood for the buiIding piping system.

Open-access reader

About this research paper

What this paper is about

The purpose of this study is to make a guide for the galvanic corrosion prevention in the building piping system. Water loopingtests were performed for 1 year. The galvanic corrosion behavior of the some piping materials were evaluated with a monitoring the corrosion potentials, the galvanic current and the corrosion appearances of the specimens. The main results are followings; 1) The galvanic current tends to decrease with time. An order of the level of the galvanic current is as following. (Higher) A1>Zn/Fe>Fe>brass>Cu and gunmetal (Lower). 2) In the case of the galvanic couple with Al as anode, Al severely corroded in hot water loop test. 3) An insulation between the anode and the cathode, and thier distance for the galvanic corrosion prevention were understood for the buiIding piping system.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study is to make a guide for the galvanic corrosion prevention in the building piping system. Water loopingtests were performed for 1 year. The galvanic corrosion behavior of the some piping materials were evaluated with a monitoring the corrosion potentials, the galvanic current and the corrosion appearances of the specimens. The main results are followings; 1) The galvanic current tends to decrease with time. An order of the level of the galvanic current is as following. (Higher) A1>Zn/Fe>Fe>brass>Cu and gunmetal (Lower). 2) In the case of the galvanic couple with Al as anode, Al severely corroded in hot water loop test. 3) An insulation between the anode and the cathode, and thier distance for the galvanic corrosion prevention were understood for the buiIding piping system.

Key concepts: Galvanic cell, Piping, Galvanic anode, Galvanic corrosion, Corrosion, Anode, Materials science, Metallurgy

Related papers

Back to paper searchBrowse research topicsOriginal source
STUDY ON GALVANIC CORROSION AND ITS PREVENTION IN BUILDING PIPING SYSTEM — Research Paper | ScholarLens