HPLC method development for the simultaneous determination and validation of Diltiazem hydrochloride and its major metabolite desacetyl Diltiazem hydrochloride
Khalid Hamad Abu-Sh
Abstract
Khalid Hamad Abu-Sh
Abstract
A stability-indicating liquid chromatographic method has been developed and validated for the determination of Diltiazem Hydrochloride and its major metabolite desacetyl Diltiazem Hydrochloride. The concentration range was 25% to 250% and the flow rate was 1.0 mL/min. The mobile phase was 650:350 v:v acetate buffer and acetonitrile, respectively. The method was proved to be linear for the determination of Diltiazem Hydrochloride and the metabolite in the range of 25% to 250% of the specified limit i.e. 0.5%; the correlation coefficient met the acceptance criteria (≥ 0.998). The smaller point in the calibration curve was optimal for low concentration samples. The limit of detection and quantification were found to be 0.0633 and 0.450 μg/mL, respectively for desacetyl Diltiazem hydrochloride and 0.0408 μg/mL and 0.2668 μg/mL, respectively for Diltiazem hydrochloride. The degradation reaction of desacetyl Diltiazem hydrochloride by stress conditions was found to be faster and more intensive than Diltiazem hydrochloride.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A stability-indicating liquid chromatographic method has been developed and validated for the determination of Diltiazem Hydrochloride and its major metabolite desacetyl Diltiazem Hydrochloride. The concentration range was 25% to 250% and the flow rate was 1.0 mL/min. The mobile phase was 650:350 v:v acetate buffer and acetonitrile, respectively. The method was proved to be linear for the determination of Diltiazem Hydrochloride and the metabolite in the range of 25% to 250% of the specified limit i.e. 0.5%; the correlation coefficient met the acceptance criteria (≥ 0.998). The smaller point in the calibration curve was optimal for low concentration samples. The limit of detection and quantification were found to be 0.0633 and 0.450 μg/mL, respectively for desacetyl Diltiazem hydrochloride and 0.0408 μg/mL and 0.2668 μg/mL, respectively for Diltiazem hydrochloride. The degradation reaction of desacetyl Diltiazem hydrochloride by stress conditions was found to be faster and more intensive than Diltiazem hydrochloride.
Key concepts: Diltiazem, Diltiazem hydrochloride, Metabolite, Chromatography, Chemistry, Hydrochloride, Detection limit, Calibration curve