2011•Der pharma chemicaRequires access

Method development and validation for simultaneous estimation of Paracetamol and Etoricoxib in pharmaceutical dosage form by RP-HPLC method

rashekhar Narajji, Manohar D. Karvekar

Open publisher page 4 citations

Abstract

A RP-HPLC method was developed for simultaneous estimation of Paracetamol and Etoricoxib tablet formulation using Phenomenex Luna C18 column (250 mm × 4.6 mm id, 5 μm particle size) and a mobile phase of methanol : water (70:30 v/v), at flow rate 1.0 ml/min with UV detection at 235 nm. The retention time (tR) of Paracetamol and Etoricoxib found to be 3.07 and 5.72 min respectively. The proposed method was validated for system suitability, specificity, linearity, accuracy, precision, LOD, LOQ and robustness. All parameters were found to be within the acceptance limit. Linearity over the concentration range 5-30 μg/ml for both Paracetamol and Etoricoxib with regression coefficient (r2) 0.9998 and 0.9994 respectively. Limit of detection (LOD) found to be 0.10 μg/ml and 0.04 μg/ml whereas limit of quantitation (LOQ) found to be 0.33 μg/ml and 0.13 μg/ml for Paracetamol and Etoricoxib respectively. The accuracy of the proposed method was determined by recovery studies and found to be 99.74%- 101.25% and 99.08%-99.21% for Paracetamol and Etoricoxib respectively.

About this research paper

What this paper is about

A RP-HPLC method was developed for simultaneous estimation of Paracetamol and Etoricoxib tablet formulation using Phenomenex Luna C18 column (250 mm × 4.6 mm id, 5 μm particle size) and a mobile phase of methanol : water (70:30 v/v), at flow rate 1.0 ml/min with UV detection at 235 nm. The retention time (tR) of Paracetamol and Etoricoxib found to be 3.07 and 5.72 min respectively. The proposed method was validated for system suitability, specificity, linearity, accuracy, precision, LOD, LOQ and robustness. All parameters were found to be within the acceptance limit. Linearity over the concentration range 5-30 μg/ml for both Paracetamol and Etoricoxib with regression coefficient (r2) 0.9998 and 0.9994 respectively. Limit of detection (LOD) found to be 0.10 μg/ml and 0.04 μg/ml whereas limit of quantitation (LOQ) found to be 0.33 μg/ml and 0.13 μg/ml for Paracetamol and Etoricoxib respectively. The accuracy of the proposed method was determined by recovery studies and found to be 99.74%- 101.25% and 99.08%-99.21% for Paracetamol and Etoricoxib respectively.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A RP-HPLC method was developed for simultaneous estimation of Paracetamol and Etoricoxib tablet formulation using Phenomenex Luna C18 column (250 mm × 4.6 mm id, 5 μm particle size) and a mobile phase of methanol : water (70:30 v/v), at flow rate 1.0 ml/min with UV detection at 235 nm. The retention time (tR) of Paracetamol and Etoricoxib found to be 3.07 and 5.72 min respectively. The proposed method was validated for system suitability, specificity, linearity, accuracy, precision, LOD, LOQ and robustness. All parameters were found to be within the acceptance limit. Linearity over the concentration range 5-30 μg/ml for both Paracetamol and Etoricoxib with regression coefficient (r2) 0.9998 and 0.9994 respectively. Limit of detection (LOD) found to be 0.10 μg/ml and 0.04 μg/ml whereas limit of quantitation (LOQ) found to be 0.33 μg/ml and 0.13 μg/ml for Paracetamol and Etoricoxib respectively. The accuracy of the proposed method was determined by recovery studies and found to be 99.74%- 101.25% and 99.08%-99.21% for Paracetamol and Etoricoxib respectively.

Key concepts: Etoricoxib, Chromatography, Detection limit, Chemistry, High-performance liquid chromatography, Dosage form, Correlation coefficient, Linearity

Related papers

Back to paper searchBrowse research topicsOriginal source
Method development and validation for simultaneous estimation of Paracetamol and Etoricoxib in pharmaceutical dosage form by RP-HPLC method — Research Paper | ScholarLens