1997PubMedRequires access

Effect of contralateral fog during refractive error assessment.

Nancy N. Chiu, Mark Rosenfield, Lyndon C. Wong

Open publisher page 3 citations

Abstract

BACKGROUND: When assessing refractive error using static retinoscopy, it is conventional to fog the contralateral eye by approximately 2.00 D to prevent a blur-driven accommodative response stimulating consensual accommodation in the tested eye. However, the effect of higher amounts of contralateral fog (e.g., in a moderate-to-high uncorrected myopic individual) during refractive error assessment is unclear. METHODS: We assessed the refractive state in 16 visually normal myopic subjects while fogging the contralateral eye between zero and 6.00 D, in 1.00 D increments. Retinoscopy was simulated by shining a streak retinoscope light into the right eye, while simultaneously measuring the refractive state of this eye objectively. RESULTS: No significant change in mean refractive state was observed for up to 5.00 D of contralateral fog. But, 6.00 D of contralateral fog produced a significant mean increase in the myopic direction of 0.13 D. Also, in three subjects, a myopic shift of approximately 0.60 D was recorded after the introduction of 6.00 D of contralateral fog. Nevertheless, the magnitude of these largest shifts in refractive error are still smaller than the previously reported degree of repeatability of static retinoscopy. CONCLUSIONS: Since large amounts of contralateral fog produced only small and clinically insignificant changes in the refractive state, the practitioner merely needs to ensure that the nontested eye is indeed fogged. The magnitude of fog present will have only a minimal effect on the final result.

About this research paper

What this paper is about

BACKGROUND: When assessing refractive error using static retinoscopy, it is conventional to fog the contralateral eye by approximately 2.00 D to prevent a blur-driven accommodative response stimulating consensual accommodation in the tested eye. However, the effect of higher amounts of contralateral fog (e.g., in a moderate-to-high uncorrected myopic individual) during refractive error assessment is unclear. METHODS: We assessed the refractive state in 16 visually normal myopic subjects while fogging the contralateral eye between zero and 6.00 D, in 1.00 D increments. Retinoscopy was simulated by shining a streak retinoscope light into the right eye, while simultaneously measuring the refractive state of this eye objectively. RESULTS: No significant change in mean refractive state was observed for up to 5.00 D of contralateral fog. But, 6.00 D of contralateral fog produced a significant mean increase in the myopic direction of 0.13 D. Also, in three subjects, a myopic shift of approximately 0.60 D was recorded after the introduction of 6.00 D of contralateral fog. Nevertheless, the magnitude of these largest shifts in refractive error are still smaller than the previously reported degree of repeatability of static retinoscopy. CONCLUSIONS: Since large amounts of contralateral fog produced only small and clinically insignificant changes in the refractive state, the practitioner merely needs to ensure that the nontested eye is indeed fogged. The magnitude of fog present will have only a minimal effect on the final result.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: When assessing refractive error using static retinoscopy, it is conventional to fog the contralateral eye by approximately 2.00 D to prevent a blur-driven accommodative response stimulating consensual accommodation in the tested eye. However, the effect of higher amounts of contralateral fog (e.g., in a moderate-to-high uncorrected myopic individual) during refractive error assessment is unclear. METHODS: We assessed the refractive state in 16 visually normal myopic subjects while fogging the contralateral eye between zero and 6.00 D, in 1.00 D increments. Retinoscopy was simulated by shining a streak retinoscope light into the right eye, while simultaneously measuring the refractive state of this eye objectively. RESULTS: No significant change in mean refractive state was observed for up to 5.00 D of contralateral fog. But, 6.00 D of contralateral fog produced a significant mean increase in the myopic direction of 0.13 D. Also, in three subjects, a myopic shift of approximately 0.60 D was recorded after the introduction of 6.00 D of contralateral fog. Nevertheless, the magnitude of these largest shifts in refractive error are still smaller than the previously reported degree of repeatability of static retinoscopy. CONCLUSIONS: Since large amounts of contralateral fog produced only small and clinically insignificant changes in the refractive state, the practitioner merely needs to ensure that the nontested eye is indeed fogged. The magnitude of fog present will have only a minimal effect on the final result.

Key concepts: Retinoscopy, Refractive error, Repeatability, Accommodation, Optometry, Refraction, Ophthalmology, Optics