Repeatability and validity of astigmatism measurements.

Jeffrey J. Walline, Kelly A Kinney, Karla Zadnik, Donald O. Mutti

Open publisher page 41 citations

Abstract

BACKGROUND: As more patients inquire about refractive surgical procedures, the measurement of astigmatism prior to surgery becomes more important in assessing refractive outcome. Knowledge of the repeatability of the astigmatism measurement allows one to distinguish a true change in cylinder power from measurement error. METHODS: Forty adults with structurally normal eyes and refractive errors were evaluated for the repeatability of astigmatic refractive error measures. Noncycloplegic and cycloplegic measurements of refractive astigmatism were made by retinoscopy, subjective refraction, and autorefraction. All measures were made at 2 visits within 2 weeks by the same examiner. Difference versus mean plots and the 95% limits of agreement of each technique determined the repeatability of a measurement and the agreement between the methods of measurement. RESULTS: The most reliable measure of astigmatic refractive error was cycloplegic autorefraction, with 95% limits of agreement of +/- 0.28 D, followed by noncycloplegic autorefraction (+/- 0.35 D) and cycloplegic subjective refraction (+/- 0.44 D). Noncycloplegic retinoscopy was the least reliable astigmatic refractive error measure, with interoccasion 95% limits of agreement of +/- 1.02 D. The most repeatable measurement of cylinder axis was cycloplegic autorefraction; none of the measurements differed by 10 degrees or more. The least repeatable measurement was noncycloplegic retinoscopy; 40% of the measurements differed by 10 degrees or more. CONCLUSION: For studies seeking to measure changes in astigmatism in normal eyes, cycloplegic autorefraction is the method of choice.

About this research paper

What this paper is about

BACKGROUND: As more patients inquire about refractive surgical procedures, the measurement of astigmatism prior to surgery becomes more important in assessing refractive outcome. Knowledge of the repeatability of the astigmatism measurement allows one to distinguish a true change in cylinder power from measurement error. METHODS: Forty adults with structurally normal eyes and refractive errors were evaluated for the repeatability of astigmatic refractive error measures. Noncycloplegic and cycloplegic measurements of refractive astigmatism were made by retinoscopy, subjective refraction, and autorefraction. All measures were made at 2 visits within 2 weeks by the same examiner. Difference versus mean plots and the 95% limits of agreement of each technique determined the repeatability of a measurement and the agreement between the methods of measurement. RESULTS: The most reliable measure of astigmatic refractive error was cycloplegic autorefraction, with 95% limits of agreement of +/- 0.28 D, followed by noncycloplegic autorefraction (+/- 0.35 D) and cycloplegic subjective refraction (+/- 0.44 D). Noncycloplegic retinoscopy was the least reliable astigmatic refractive error measure, with interoccasion 95% limits of agreement of +/- 1.02 D. The most repeatable measurement of cylinder axis was cycloplegic autorefraction; none of the measurements differed by 10 degrees or more. The least repeatable measurement was noncycloplegic retinoscopy; 40% of the measurements differed by 10 degrees or more. CONCLUSION: For studies seeking to measure changes in astigmatism in normal eyes, cycloplegic autorefraction is the method of choice.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: As more patients inquire about refractive surgical procedures, the measurement of astigmatism prior to surgery becomes more important in assessing refractive outcome. Knowledge of the repeatability of the astigmatism measurement allows one to distinguish a true change in cylinder power from measurement error. METHODS: Forty adults with structurally normal eyes and refractive errors were evaluated for the repeatability of astigmatic refractive error measures. Noncycloplegic and cycloplegic measurements of refractive astigmatism were made by retinoscopy, subjective refraction, and autorefraction. All measures were made at 2 visits within 2 weeks by the same examiner. Difference versus mean plots and the 95% limits of agreement of each technique determined the repeatability of a measurement and the agreement between the methods of measurement. RESULTS: The most reliable measure of astigmatic refractive error was cycloplegic autorefraction, with 95% limits of agreement of +/- 0.28 D, followed by noncycloplegic autorefraction (+/- 0.35 D) and cycloplegic subjective refraction (+/- 0.44 D). Noncycloplegic retinoscopy was the least reliable astigmatic refractive error measure, with interoccasion 95% limits of agreement of +/- 1.02 D. The most repeatable measurement of cylinder axis was cycloplegic autorefraction; none of the measurements differed by 10 degrees or more. The least repeatable measurement was noncycloplegic retinoscopy; 40% of the measurements differed by 10 degrees or more. CONCLUSION: For studies seeking to measure changes in astigmatism in normal eyes, cycloplegic autorefraction is the method of choice.

Key concepts: Retinoscopy, Repeatability, Limits of agreement, Subjective refraction, Astigmatism, Refractive error, Refraction, Optometry