Current Transformer Saturation Effects on Coordinating Time Interval

Terrence Smith, Richard Hunt

Open publisher page 19 citations

Abstract

The primary function of protective devices is to remove faulted equipment from the electrical system. It is typically very advantageous for these devices to isolate as small of a section of the electrical system as possible. Overcurrent protection is the most common protection function used, as faulted equipment typically results in a large short circuit current. When overcurrent protection is employed, the overcurrent protection is typically coordinated with time so that the devices closest to the fault will operate and isolate only that section of equipment before devices farther from the fault operate and isolate larger pieces of the system. These time overcurrent devices must also be coordinated with damage curves for equipment such as buses and cables to clear the fault before the overcurrent can cause damage to the equipment. This concept of time coordination of overcurrent is well understood, and there are general guidelines applied to account for measurement error and other inaccuracies. The reduced signal levels provided to relays due to current transformer (CT) saturation are normally not considered during coordination studies. This reduced signal level will result in slower than desired operation of protective relays. Feeder relays could trip slower than upstream devices, isolating more of the power system than intended, or could allow primary equipment to be damaged before tripping. This paper will review the concept of coordinating time overcurrent relays and then discuss the concept of loss of coordination associated with CT saturation. This paper will model CT saturation from actual installations using the IEEE Power System Relaying Committee CT Saturation Calculator tool. This model data will be used to estimate the performance of protective relays. This paper will discuss methods to improve the coordination of overcurrent relays when faced with significant CT saturation.

About this research paper

What this paper is about

The primary function of protective devices is to remove faulted equipment from the electrical system. It is typically very advantageous for these devices to isolate as small of a section of the electrical system as possible. Overcurrent protection is the most common protection function used, as faulted equipment typically results in a large short circuit current. When overcurrent protection is employed, the overcurrent protection is typically coordinated with time so that the devices closest to the fault will operate and isolate only that section of equipment before devices farther from the fault operate and isolate larger pieces of the system. These time overcurrent devices must also be coordinated with damage curves for equipment such as buses and cables to clear the fault before the overcurrent can cause damage to the equipment. This concept of time coordination of overcurrent is well understood, and there are general guidelines applied to account for measurement error and other inaccuracies. The reduced signal levels provided to relays due to current transformer (CT) saturation are normally not considered during coordination studies. This reduced signal level will result in slower than desired operation of protective relays. Feeder relays could trip slower than upstream devices, isolating more of the power system than intended, or could allow primary equipment to be damaged before tripping. This paper will review the concept of coordinating time overcurrent relays and then discuss the concept of loss of coordination associated with CT saturation. This paper will model CT saturation from actual installations using the IEEE Power System Relaying Committee CT Saturation Calculator tool. This model data will be used to estimate the performance of protective relays. This paper will discuss methods to improve the coordination of overcurrent relays when faced with significant CT saturation.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The primary function of protective devices is to remove faulted equipment from the electrical system. It is typically very advantageous for these devices to isolate as small of a section of the electrical system as possible. Overcurrent protection is the most common protection function used, as faulted equipment typically results in a large short circuit current. When overcurrent protection is employed, the overcurrent protection is typically coordinated with time so that the devices closest to the fault will operate and isolate only that section of equipment before devices farther from the fault operate and isolate larger pieces of the system. These time overcurrent devices must also be coordinated with damage curves for equipment such as buses and cables to clear the fault before the overcurrent can cause damage to the equipment. This concept of time coordination of overcurrent is well understood, and there are general guidelines applied to account for measurement error and other inaccuracies. The reduced signal levels provided to relays due to current transformer (CT) saturation are normally not considered during coordination studies. This reduced signal level will result in slower than desired operation of protective relays. Feeder relays could trip slower than upstream devices, isolating more of the power system than intended, or could allow primary equipment to be damaged before tripping. This paper will review the concept of coordinating time overcurrent relays and then discuss the concept of loss of coordination associated with CT saturation. This paper will model CT saturation from actual installations using the IEEE Power System Relaying Committee CT Saturation Calculator tool. This model data will be used to estimate the performance of protective relays. This paper will discuss methods to improve the coordination of overcurrent relays when faced with significant CT saturation.

Key concepts: Overcurrent, Protective relay, Tripping, Current transformer, Relay, Transformer, Power-system protection, Engineering