2006Unpublished venueOpen access

Saturation of Current Transformers and its Impact on Digital Overcurrent Relays

Ibrahim El‐Amin, Nabil H. Al-Abbas

Open full text 23 citations

Abstract

Improper selections of current transformers will result in CT's saturation during fault conditions which can affect protection relays operations. With the absence of clear and practical guidelines for CT's selections, designers are facing great difficulties to ensure proper operations of digital relays. The impact of CT saturation is different for different protection devices and schemes. This paper investigates the influence of CT saturation on over-current digital relays, in distribution systems where loads are relatively small and connected to switch-gears with high short circuit levels. A research was performed to verify the operations of instantaneous and time-delayed over-current digital relays to ensure coordination with other devices and safe isolations of faults. It is shown that instantaneous digital relays will perform properly with a relatively small CT's. A criterion for selecting CT's for instantaneous digital over-current relays operations is presented. However, time-delayed over-current relays will be significantly impacted by CT's saturation and special care shall be taken to achieve coordination with other devices

Open-access reader

About this research paper

What this paper is about

Improper selections of current transformers will result in CT's saturation during fault conditions which can affect protection relays operations. With the absence of clear and practical guidelines for CT's selections, designers are facing great difficulties to ensure proper operations of digital relays. The impact of CT saturation is different for different protection devices and schemes. This paper investigates the influence of CT saturation on over-current digital relays, in distribution systems where loads are relatively small and connected to switch-gears with high short circuit levels. A research was performed to verify the operations of instantaneous and time-delayed over-current digital relays to ensure coordination with other devices and safe isolations of faults. It is shown that instantaneous digital relays will perform properly with a relatively small CT's. A criterion for selecting CT's for instantaneous digital over-current relays operations is presented. However, time-delayed over-current relays will be significantly impacted by CT's saturation and special care shall be taken to achieve coordination with other devices

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Improper selections of current transformers will result in CT's saturation during fault conditions which can affect protection relays operations. With the absence of clear and practical guidelines for CT's selections, designers are facing great difficulties to ensure proper operations of digital relays. The impact of CT saturation is different for different protection devices and schemes. This paper investigates the influence of CT saturation on over-current digital relays, in distribution systems where loads are relatively small and connected to switch-gears with high short circuit levels. A research was performed to verify the operations of instantaneous and time-delayed over-current digital relays to ensure coordination with other devices and safe isolations of faults. It is shown that instantaneous digital relays will perform properly with a relatively small CT's. A criterion for selecting CT's for instantaneous digital over-current relays operations is presented. However, time-delayed over-current relays will be significantly impacted by CT's saturation and special care shall be taken to achieve coordination with other devices

Key concepts: Overcurrent, Protective relay, Current transformer, Transformer, Power-system protection, Saturation (graph theory), Electrical engineering, Digital protective relay

Related papers

Back to paper searchBrowse research topicsOriginal source
Saturation of Current Transformers and its Impact on Digital Overcurrent Relays — Research Paper | ScholarLens