2016•Unpublished venueRequires access

Simulation studies on very fast transient overvoltage

Baina He, Yunwei Zhao, Guichun Huang, Yuanchao Hu, Yunzhu An

Open publisher page 4 citations

Abstract

Very fast transient overvoltage (VFTO) not only influence the operating reliability of GIS, but also causes great threat to the insulation of the high-voltage equipment, especially to windings of the transformer. Taking a 550kV GIS substation as the object, VFTO characteristics, generation mechanism and influencing factors are studied in the paper. Based on the structure of GIS, the simulation model of GIS internal structure is established, and the fast transient overvoltage caused by GIS disconnector operation is simulated. The influences of the structure parameters on the fast transient overvoltage is analyzed, and the influence factors of VFTO are analyzed from the point of view of internal and external GIS.

About this research paper

What this paper is about

Very fast transient overvoltage (VFTO) not only influence the operating reliability of GIS, but also causes great threat to the insulation of the high-voltage equipment, especially to windings of the transformer. Taking a 550kV GIS substation as the object, VFTO characteristics, generation mechanism and influencing factors are studied in the paper. Based on the structure of GIS, the simulation model of GIS internal structure is established, and the fast transient overvoltage caused by GIS disconnector operation is simulated. The influences of the structure parameters on the fast transient overvoltage is analyzed, and the influence factors of VFTO are analyzed from the point of view of internal and external GIS.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Very fast transient overvoltage (VFTO) not only influence the operating reliability of GIS, but also causes great threat to the insulation of the high-voltage equipment, especially to windings of the transformer. Taking a 550kV GIS substation as the object, VFTO characteristics, generation mechanism and influencing factors are studied in the paper. Based on the structure of GIS, the simulation model of GIS internal structure is established, and the fast transient overvoltage caused by GIS disconnector operation is simulated. The influences of the structure parameters on the fast transient overvoltage is analyzed, and the influence factors of VFTO are analyzed from the point of view of internal and external GIS.

Key concepts: Overvoltage, Transient (computer programming), Transient analysis, Computer science, Electrical engineering, Voltage, Transient response, Engineering