Research on partial discharge characteristics of protrusion defect in GIS under oscillating lightning impulse voltage
Mengchen Hu, Xutao Han, Qiuyang Li, Shengfu Wang, Yao Chen, Junhao Li
Abstract
Mengchen Hu, Xutao Han, Qiuyang Li, Shengfu Wang, Yao Chen, Junhao Li
Abstract
In order to ensure the safe operation of the gas insulated switchgear (GIS), on-site impulse withstand voltage test is becoming more and more important. Oscillating impulse voltage is very suitable for the field test due to its high generating efficiency. By detecting the partial discharge when conducting on-site impulse withstand voltage test, the insulation state of GIS can be overall known. The protrusion is a typical aPublication Event Topic :nd harmful defect in GIS, so it is very significant to research the partial discharge characteristics of protrusion in GIS under oscillating lightning impulse voltage. In this paper, we applied oscillating lightning impulse voltage on a 330kV GIS which was set a protrusion at the conductor and we measured the partial discharge by the inner UHF sensor at the same time. We analyze the variation of discharge position, maximum discharge amplitude and discharge number with the increasing of voltage and compare the results of different frequencies voltage. Our studies show that the partial discharges mainly occur at the peak of the oscillating lightning impulse voltage. With the increasing of the voltage amplitude, the maximum discharge amplitude and discharge number also increase. And with the increasing of the voltage frequency, the partial discharge inception voltage increases. The results of this paper are helpful for the on-site impulse withstand voltage test.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In order to ensure the safe operation of the gas insulated switchgear (GIS), on-site impulse withstand voltage test is becoming more and more important. Oscillating impulse voltage is very suitable for the field test due to its high generating efficiency. By detecting the partial discharge when conducting on-site impulse withstand voltage test, the insulation state of GIS can be overall known. The protrusion is a typical aPublication Event Topic :nd harmful defect in GIS, so it is very significant to research the partial discharge characteristics of protrusion in GIS under oscillating lightning impulse voltage. In this paper, we applied oscillating lightning impulse voltage on a 330kV GIS which was set a protrusion at the conductor and we measured the partial discharge by the inner UHF sensor at the same time. We analyze the variation of discharge position, maximum discharge amplitude and discharge number with the increasing of voltage and compare the results of different frequencies voltage. Our studies show that the partial discharges mainly occur at the peak of the oscillating lightning impulse voltage. With the increasing of the voltage amplitude, the maximum discharge amplitude and discharge number also increase. And with the increasing of the voltage frequency, the partial discharge inception voltage increases. The results of this paper are helpful for the on-site impulse withstand voltage test.
Key concepts: Partial discharge, Impulse (physics), Switchgear, Voltage, Amplitude, Electrical engineering, Impulse generator, Acoustics