Heating Problems When Using the Converter Station Grounding Grid as the HVDC Grounding Electrode

Huaifei Chen, Zhuohong Pan, Huifan Xie, Bo Tan, Xuefang Tong

Open full text 0 citations

Abstract

To ensure the safe and stable operation of HVDC systems without grounding electrode, this paper proposes a concept of replacing the HVDC grounding electrode with the converter station's grounding grid.This paper studies the technical problems of heating problem of grounding grid.The result shows that the ground down lead can't bear DC current in a long-term, which means the ground return current utilizes the feeder cable to run into the grid.The permitted operating time when the ground return current is 3000A should be limited within 10 minutes.If an HVDC link uses bipole blocking control strategy, the research helps eliminating the HVDC grounding electrode, which will greatly save the cost.

Open-access reader

About this research paper

What this paper is about

To ensure the safe and stable operation of HVDC systems without grounding electrode, this paper proposes a concept of replacing the HVDC grounding electrode with the converter station's grounding grid.This paper studies the technical problems of heating problem of grounding grid.The result shows that the ground down lead can't bear DC current in a long-term, which means the ground return current utilizes the feeder cable to run into the grid.The permitted operating time when the ground return current is 3000A should be limited within 10 minutes.If an HVDC link uses bipole blocking control strategy, the research helps eliminating the HVDC grounding electrode, which will greatly save the cost.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To ensure the safe and stable operation of HVDC systems without grounding electrode, this paper proposes a concept of replacing the HVDC grounding electrode with the converter station's grounding grid.This paper studies the technical problems of heating problem of grounding grid.The result shows that the ground down lead can't bear DC current in a long-term, which means the ground return current utilizes the feeder cable to run into the grid.The permitted operating time when the ground return current is 3000A should be limited within 10 minutes.If an HVDC link uses bipole blocking control strategy, the research helps eliminating the HVDC grounding electrode, which will greatly save the cost.