2010Nanfang dianwang jishuRequires access

Research on the Improvement of Secondary Equipment Grounding Mode at Suidong Converter Station

Qingbiao Lin

Open publisher page 0 citations

Abstract

Analyzing the need of secondary equipment grounding,this paper concludes that for a good equipment grounding,the grounding resistance should be minimal,and some measures are also required such as to deploy a dedicated equipotential grounding network for reducing the potential difference between two grounding points of the equipment,and to connect the both ends of cable shield to the network for suppressing the electromagnetic interference and over-voltage invasion.For the actual case of Suidong Converter Station,certain suggestions to improve its grounding mode are given with an equipotential grounding network contact map of the whole station.

About this research paper

What this paper is about

Analyzing the need of secondary equipment grounding,this paper concludes that for a good equipment grounding,the grounding resistance should be minimal,and some measures are also required such as to deploy a dedicated equipotential grounding network for reducing the potential difference between two grounding points of the equipment,and to connect the both ends of cable shield to the network for suppressing the electromagnetic interference and over-voltage invasion.For the actual case of Suidong Converter Station,certain suggestions to improve its grounding mode are given with an equipotential grounding network contact map of the whole station.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Analyzing the need of secondary equipment grounding,this paper concludes that for a good equipment grounding,the grounding resistance should be minimal,and some measures are also required such as to deploy a dedicated equipotential grounding network for reducing the potential difference between two grounding points of the equipment,and to connect the both ends of cable shield to the network for suppressing the electromagnetic interference and over-voltage invasion.For the actual case of Suidong Converter Station,certain suggestions to improve its grounding mode are given with an equipotential grounding network contact map of the whole station.

Key concepts: Ground, Equipotential, Electrical engineering, Engineering, Mode (computer interface), Interference (communication), Electromagnetic interference, Shield

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on the Improvement of Secondary Equipment Grounding Mode at Suidong Converter Station — Research Paper | ScholarLens