2010Unpublished venueRequires access

The analysis of specific grounding fault and Petersen on ARC grounding out arc

Runhua Wang

Open publisher page 1 citations

Abstract

10KV–35KV Medium Voltage Distribution Network neutral point grounding modes choice is a systems engineering. When ARC grounding fault happens, neutral through Petersen coil can carry out effective blow has always been a focus. By arc grounding in the neutral through Petersen coil process, Results are as long as proper control of relative roughness. Neutral through Arc - suppression coil grounding ways to better control of ARC grounding fault without affecting the reliability of power supply. Study on small current earth fault line selection and field failure data of monitoring and control system of records. Analysis of intermittent arc grounding and unbalanced current grounding and development of grounding and the cause of formation of ring earth fault and fault phenomenon and zero - sequence voltage and current situation. Description of single - phase to ground fault in small current grounding system is a complex one, development and the process of change. Only attaches importance to this process is enough to improve the reliability and accuracy of line selection.

About this research paper

What this paper is about

10KV–35KV Medium Voltage Distribution Network neutral point grounding modes choice is a systems engineering. When ARC grounding fault happens, neutral through Petersen coil can carry out effective blow has always been a focus. By arc grounding in the neutral through Petersen coil process, Results are as long as proper control of relative roughness. Neutral through Arc - suppression coil grounding ways to better control of ARC grounding fault without affecting the reliability of power supply. Study on small current earth fault line selection and field failure data of monitoring and control system of records. Analysis of intermittent arc grounding and unbalanced current grounding and development of grounding and the cause of formation of ring earth fault and fault phenomenon and zero - sequence voltage and current situation. Description of single - phase to ground fault in small current grounding system is a complex one, development and the process of change. Only attaches importance to this process is enough to improve the reliability and accuracy of line selection.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

10KV–35KV Medium Voltage Distribution Network neutral point grounding modes choice is a systems engineering. When ARC grounding fault happens, neutral through Petersen coil can carry out effective blow has always been a focus. By arc grounding in the neutral through Petersen coil process, Results are as long as proper control of relative roughness. Neutral through Arc - suppression coil grounding ways to better control of ARC grounding fault without affecting the reliability of power supply. Study on small current earth fault line selection and field failure data of monitoring and control system of records. Analysis of intermittent arc grounding and unbalanced current grounding and development of grounding and the cause of formation of ring earth fault and fault phenomenon and zero - sequence voltage and current situation. Description of single - phase to ground fault in small current grounding system is a complex one, development and the process of change. Only attaches importance to this process is enough to improve the reliability and accuracy of line selection.

Key concepts: Ground, Earthing system, Arc suppression, Electromagnetic coil, Fault (geology), Electrical engineering, Reliability (semiconductor), Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
The analysis of specific grounding fault and Petersen on ARC grounding out arc — Research Paper | ScholarLens