Estimation of Design Parameters of Single-Phase Distribution Transformers From Terminal Measurements
Reza Kazemi, Saeed Jazebi, Digvijay Deswal, Francisco de León
Abstract
Reza Kazemi, Saeed Jazebi, Digvijay Deswal, Francisco de León
Abstract
In this paper, a novel method is proposed for the estimation of the design parameters of single-phase distribution transformers using data acquired from terminal measurements along with nameplate data and external tank dimensions. Transformer parameters that can be measured from terminals, for example, leakage inductance, saturation inductance, and winding resistance, are considered first. These parameters are analytically correlated with the geometrical information of the transformer structure. A system of nonlinear equations is derived accordingly. Winding dimensions and the number of turns are computed with acceptable engineering accuracy. The core dimensions (including its cross-sectional area) are calculated using winding information. The obtained data can be utilized to develop white- or gray-box models to be used in the investigation of the thermal and/or electromagnetic behavior of power transformers as presented in several research studies published to date. Examples on laboratory and utility-grade transformers are shown for illustration and validation of the proposed design parameter estimation method.
OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In this paper, a novel method is proposed for the estimation of the design parameters of single-phase distribution transformers using data acquired from terminal measurements along with nameplate data and external tank dimensions. Transformer parameters that can be measured from terminals, for example, leakage inductance, saturation inductance, and winding resistance, are considered first. These parameters are analytically correlated with the geometrical information of the transformer structure. A system of nonlinear equations is derived accordingly. Winding dimensions and the number of turns are computed with acceptable engineering accuracy. The core dimensions (including its cross-sectional area) are calculated using winding information. The obtained data can be utilized to develop white- or gray-box models to be used in the investigation of the thermal and/or electromagnetic behavior of power transformers as presented in several research studies published to date. Examples on laboratory and utility-grade transformers are shown for illustration and validation of the proposed design parameter estimation method.
Key concepts: Transformer, Distribution transformer, Inductance, Leakage inductance, Electromagnetic coil, Engineering, Electronic engineering, Energy efficient transformer