2016•IEEE Transactions on Power DeliveryRequires access

Estimation of Design Parameters of Single-Phase Distribution Transformers From Terminal Measurements

Reza Kazemi, Saeed Jazebi, Digvijay Deswal, Francisco de León

Open publisher page 22 citations

Abstract

In this paper, a novel method is proposed for the estimation of the design parameters of single-phase distribution transformers using data acquired from terminal measurements along with nameplate data and external tank dimensions. Transformer parameters that can be measured from terminals, for example, leakage inductance, saturation inductance, and winding resistance, are considered first. These parameters are analytically correlated with the geometrical information of the transformer structure. A system of nonlinear equations is derived accordingly. Winding dimensions and the number of turns are computed with acceptable engineering accuracy. The core dimensions (including its cross-sectional area) are calculated using winding information. The obtained data can be utilized to develop white- or gray-box models to be used in the investigation of the thermal and/or electromagnetic behavior of power transformers as presented in several research studies published to date. Examples on laboratory and utility-grade transformers are shown for illustration and validation of the proposed design parameter estimation method.

About this research paper

What this paper is about

In this paper, a novel method is proposed for the estimation of the design parameters of single-phase distribution transformers using data acquired from terminal measurements along with nameplate data and external tank dimensions. Transformer parameters that can be measured from terminals, for example, leakage inductance, saturation inductance, and winding resistance, are considered first. These parameters are analytically correlated with the geometrical information of the transformer structure. A system of nonlinear equations is derived accordingly. Winding dimensions and the number of turns are computed with acceptable engineering accuracy. The core dimensions (including its cross-sectional area) are calculated using winding information. The obtained data can be utilized to develop white- or gray-box models to be used in the investigation of the thermal and/or electromagnetic behavior of power transformers as presented in several research studies published to date. Examples on laboratory and utility-grade transformers are shown for illustration and validation of the proposed design parameter estimation method.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, a novel method is proposed for the estimation of the design parameters of single-phase distribution transformers using data acquired from terminal measurements along with nameplate data and external tank dimensions. Transformer parameters that can be measured from terminals, for example, leakage inductance, saturation inductance, and winding resistance, are considered first. These parameters are analytically correlated with the geometrical information of the transformer structure. A system of nonlinear equations is derived accordingly. Winding dimensions and the number of turns are computed with acceptable engineering accuracy. The core dimensions (including its cross-sectional area) are calculated using winding information. The obtained data can be utilized to develop white- or gray-box models to be used in the investigation of the thermal and/or electromagnetic behavior of power transformers as presented in several research studies published to date. Examples on laboratory and utility-grade transformers are shown for illustration and validation of the proposed design parameter estimation method.

Key concepts: Transformer, Distribution transformer, Inductance, Leakage inductance, Electromagnetic coil, Engineering, Electronic engineering, Energy efficient transformer

Related papers

Back to paper searchBrowse research topicsOriginal source
Estimation of Design Parameters of Single-Phase Distribution Transformers From Terminal Measurements — Research Paper | ScholarLens