2017Unpublished venueRequires access

Design and implementation of a multi winding high frequency transformer for MPSST application

Mohammad Rashidi, Abedalsalam Bani‐Ahmed, Robabeh Nasiri, Azadeh Mazaheri, Adel Nasiri

Open publisher page 25 citations

Abstract

Development of the new generation of high power and high frequency power electronic switches along with the need for compact controllable converters for utilization of distributed energy resources in the grid, have led to significant developments in the area of solid state transformers in the last years. The design process of a high frequency transformer as the main element in the solid state transformer is illustrated in this article. A multi winding transformer for multiport SST application is designed, studied and built in this research. In a MPSST several windings feed the core. As the result, coupling coefficient between each pair of windings, become an important factor which is studied in this study. Since the transformer is designed for high frequency applications, the power loss in the wire and core of the transformer increases as the result of higher skin effect and eddy current loss in high frequency. Three important factors in the design of HF transformer for MPSST are discussed in the paper. First, four different possible core materials are compared based on their flux density, frequency range, loss and price. Then the cable selection is illustrated and finally, different winding placement and distribution on the same core are suggested and the inductance and coupling coefficient matrices are calculated using ANSYS Maxwell 3D simulation. The transformer is built in the lab and the inductance values matches the expected values from the simulation.

About this research paper

What this paper is about

Development of the new generation of high power and high frequency power electronic switches along with the need for compact controllable converters for utilization of distributed energy resources in the grid, have led to significant developments in the area of solid state transformers in the last years. The design process of a high frequency transformer as the main element in the solid state transformer is illustrated in this article. A multi winding transformer for multiport SST application is designed, studied and built in this research. In a MPSST several windings feed the core. As the result, coupling coefficient between each pair of windings, become an important factor which is studied in this study. Since the transformer is designed for high frequency applications, the power loss in the wire and core of the transformer increases as the result of higher skin effect and eddy current loss in high frequency. Three important factors in the design of HF transformer for MPSST are discussed in the paper. First, four different possible core materials are compared based on their flux density, frequency range, loss and price. Then the cable selection is illustrated and finally, different winding placement and distribution on the same core are suggested and the inductance and coupling coefficient matrices are calculated using ANSYS Maxwell 3D simulation. The transformer is built in the lab and the inductance values matches the expected values from the simulation.

Why it matters

OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Development of the new generation of high power and high frequency power electronic switches along with the need for compact controllable converters for utilization of distributed energy resources in the grid, have led to significant developments in the area of solid state transformers in the last years. The design process of a high frequency transformer as the main element in the solid state transformer is illustrated in this article. A multi winding transformer for multiport SST application is designed, studied and built in this research. In a MPSST several windings feed the core. As the result, coupling coefficient between each pair of windings, become an important factor which is studied in this study. Since the transformer is designed for high frequency applications, the power loss in the wire and core of the transformer increases as the result of higher skin effect and eddy current loss in high frequency. Three important factors in the design of HF transformer for MPSST are discussed in the paper. First, four different possible core materials are compared based on their flux density, frequency range, loss and price. Then the cable selection is illustrated and finally, different winding placement and distribution on the same core are suggested and the inductance and coupling coefficient matrices are calculated using ANSYS Maxwell 3D simulation. The transformer is built in the lab and the inductance values matches the expected values from the simulation.

Key concepts: Energy efficient transformer, Distribution transformer, Delta-wye transformer, Transformer types, Leakage inductance, Transformer, Electromagnetic coil, Inductance

Related papers

Back to paper searchBrowse research topicsOriginal source
Design and implementation of a multi winding high frequency transformer for MPSST application — Research Paper | ScholarLens