2010Unpublished venueRequires access

Characterisation of a Broad Energy Germanium (BEGe) detector. Simulation and experimental results

D. Barrientos, I.C. Sagrado, A.J. Boston, H.C. Boston, B. Quintana, C. Unsworth, Sunghwan Moon, J.R. Cresswell

Open publisher page 3 citations

Abstract

Characterisation of High Purity Germanium (HPGe) detectors in order to predict the response of the detector to different gamma ray interactions is one of the current goals in the Nuclear physics community. This purpose includes a theoretical study of the detector from the simulation point of view and an experimental stage to validate the goodness of the considerations performed. In this work, the detector under study is a Broad Energy Germanium detector. The simulation has been performed with the Multi Geometry Simulation (MGS) program, that provides the predicted electric field and the charge pulse shapes expected at the contacts for a given detector geometry. The experimental setup included two type of scans with different collimated sources across its front and bottom faces, storing the data with a fully digital acquisition system. Subsequent data analysis and the use of Pulse Shape Analysis(PSA) techniques has allowed the knowledge of internal characteristics of the detector such as the contact limits or orientation of crystallographic axes; as well as the comparison between experimental and simulated pulse shapes.

About this research paper

What this paper is about

Characterisation of High Purity Germanium (HPGe) detectors in order to predict the response of the detector to different gamma ray interactions is one of the current goals in the Nuclear physics community. This purpose includes a theoretical study of the detector from the simulation point of view and an experimental stage to validate the goodness of the considerations performed. In this work, the detector under study is a Broad Energy Germanium detector. The simulation has been performed with the Multi Geometry Simulation (MGS) program, that provides the predicted electric field and the charge pulse shapes expected at the contacts for a given detector geometry. The experimental setup included two type of scans with different collimated sources across its front and bottom faces, storing the data with a fully digital acquisition system. Subsequent data analysis and the use of Pulse Shape Analysis(PSA) techniques has allowed the knowledge of internal characteristics of the detector such as the contact limits or orientation of crystallographic axes; as well as the comparison between experimental and simulated pulse shapes.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Characterisation of High Purity Germanium (HPGe) detectors in order to predict the response of the detector to different gamma ray interactions is one of the current goals in the Nuclear physics community. This purpose includes a theoretical study of the detector from the simulation point of view and an experimental stage to validate the goodness of the considerations performed. In this work, the detector under study is a Broad Energy Germanium detector. The simulation has been performed with the Multi Geometry Simulation (MGS) program, that provides the predicted electric field and the charge pulse shapes expected at the contacts for a given detector geometry. The experimental setup included two type of scans with different collimated sources across its front and bottom faces, storing the data with a fully digital acquisition system. Subsequent data analysis and the use of Pulse Shape Analysis(PSA) techniques has allowed the knowledge of internal characteristics of the detector such as the contact limits or orientation of crystallographic axes; as well as the comparison between experimental and simulated pulse shapes.

Key concepts: Detector, Semiconductor detector, Collimated light, Germanium, Optics, Energy (signal processing), Physics, Data acquisition

Related papers

Back to paper searchBrowse research topicsOriginal source
Characterisation of a Broad Energy Germanium (BEGe) detector. Simulation and experimental results — Research Paper | ScholarLens