1970IEEE Transactions on Nuclear ScienceRequires access

Gamma Ray Detectors Made from High Purity Germanium

R.D. Baertsch, R. N. Hall

Open publisher page 51 citations

Abstract

A solution regrowth technique for growing P+ and N+ contacts on high purity germanium is described. Copper contamination of the high purity germanium is minimized by using KCN to remove copper from the surface of the germanium and by the gettering ability of molten indium in contact with the germanium. Diodes with leakage currents as low as 3 × 10-11 amp for 2000 volts applied to a fully depleted 4 mm thick detector have been fabricated. Preliminary measurements show that the resolution obtained with these diodes is comparable to the best Li drifted germanium detectors at 60 keV and 122 keV. Diodes have been warmed to room temperature as many as five times with no degradation in resolution.

About this research paper

What this paper is about

A solution regrowth technique for growing P+ and N+ contacts on high purity germanium is described. Copper contamination of the high purity germanium is minimized by using KCN to remove copper from the surface of the germanium and by the gettering ability of molten indium in contact with the germanium. Diodes with leakage currents as low as 3 × 10-11 amp for 2000 volts applied to a fully depleted 4 mm thick detector have been fabricated. Preliminary measurements show that the resolution obtained with these diodes is comparable to the best Li drifted germanium detectors at 60 keV and 122 keV. Diodes have been warmed to room temperature as many as five times with no degradation in resolution.

Why it matters

OpenAlex reports 51 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A solution regrowth technique for growing P+ and N+ contacts on high purity germanium is described. Copper contamination of the high purity germanium is minimized by using KCN to remove copper from the surface of the germanium and by the gettering ability of molten indium in contact with the germanium. Diodes with leakage currents as low as 3 × 10-11 amp for 2000 volts applied to a fully depleted 4 mm thick detector have been fabricated. Preliminary measurements show that the resolution obtained with these diodes is comparable to the best Li drifted germanium detectors at 60 keV and 122 keV. Diodes have been warmed to room temperature as many as five times with no degradation in resolution.

Key concepts: Germanium, Semiconductor detector, Materials science, Diode, Getter, Copper, Indium, Optoelectronics

Related papers

Back to paper searchBrowse research topicsOriginal source
Gamma Ray Detectors Made from High Purity Germanium — Research Paper | ScholarLens