2016•Drug ResearchRequires access

A Sensitive Triple Quadrupole Liquid Chromatography Mass Spectrometric Method for the Estimation of Valproic Acid in K2EDTA Human Plasma using Furosemide as the Internal Standard

K. Soni, N. Patel, Kanchan Singh, Anil Jha, Hasmukh B. Patel, R. Gupta, Nuggehally R. Srinivas

Open publisher page 4 citations

Abstract

A valproic acid is primarily being used in the treatment of epilepsy is a histone deacetylase inhibitor and it is under investigation for treatment of HIV and various cancer indications. A specific, sensitive and fast bioanalytical LC-MS/MS method was developed with furosemide as an internal standard (IS) and thoroughly validated for the quantitation of valproic acid using turbo ion spray in negative ion mode. The analyte and IS was extracted using protein precipitation. The chromatographic separation of analytes from extracted matrix was achieved using a Chromolith RP 18e (2.0×50 mm) column with a gradient mobile phase comprising of acetonitrile and purified water with acetic acid. The elution of both peaks was achieved within 5.2 min, with retention times of 2.55 min and 1.67 min for valproic acid and IS, respectively. Quantitation of valproic acid was achieved by the pseudo SRM transition pairs ( m/z 142.8→ m/z 142.8), and SRM transition pair ( m/z 328.8 → m/z 204.6) for internal standard.The calibration standards of valproic acid showed linear over a range from 50 to 40 000 ng/mL, with a lower limit of quantitation of 50 ng/mL with accuracy of 3.74% and precision of 5.06%. The bias for inter- and intra-batch assays was 1.24–6.14% and 3.85–11.84%, respectively; while the corresponding precision was 2.56–16.37% and 1.29–11.34%, respectively. The developed method was used to monitor valproic acid levels in clinical samples. Because of higher sensitivity, this method can be used for therapeutic drug monitoring in pediatric subjects.

About this research paper

What this paper is about

A valproic acid is primarily being used in the treatment of epilepsy is a histone deacetylase inhibitor and it is under investigation for treatment of HIV and various cancer indications. A specific, sensitive and fast bioanalytical LC-MS/MS method was developed with furosemide as an internal standard (IS) and thoroughly validated for the quantitation of valproic acid using turbo ion spray in negative ion mode. The analyte and IS was extracted using protein precipitation. The chromatographic separation of analytes from extracted matrix was achieved using a Chromolith RP 18e (2.0×50 mm) column with a gradient mobile phase comprising of acetonitrile and purified water with acetic acid. The elution of both peaks was achieved within 5.2 min, with retention times of 2.55 min and 1.67 min for valproic acid and IS, respectively. Quantitation of valproic acid was achieved by the pseudo SRM transition pairs ( m/z 142.8→ m/z 142.8), and SRM transition pair ( m/z 328.8 → m/z 204.6) for internal standard.The calibration standards of valproic acid showed linear over a range from 50 to 40 000 ng/mL, with a lower limit of quantitation of 50 ng/mL with accuracy of 3.74% and precision of 5.06%. The bias for inter- and intra-batch assays was 1.24–6.14% and 3.85–11.84%, respectively; while the corresponding precision was 2.56–16.37% and 1.29–11.34%, respectively. The developed method was used to monitor valproic acid levels in clinical samples. Because of higher sensitivity, this method can be used for therapeutic drug monitoring in pediatric subjects.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A valproic acid is primarily being used in the treatment of epilepsy is a histone deacetylase inhibitor and it is under investigation for treatment of HIV and various cancer indications. A specific, sensitive and fast bioanalytical LC-MS/MS method was developed with furosemide as an internal standard (IS) and thoroughly validated for the quantitation of valproic acid using turbo ion spray in negative ion mode. The analyte and IS was extracted using protein precipitation. The chromatographic separation of analytes from extracted matrix was achieved using a Chromolith RP 18e (2.0×50 mm) column with a gradient mobile phase comprising of acetonitrile and purified water with acetic acid. The elution of both peaks was achieved within 5.2 min, with retention times of 2.55 min and 1.67 min for valproic acid and IS, respectively. Quantitation of valproic acid was achieved by the pseudo SRM transition pairs ( m/z 142.8→ m/z 142.8), and SRM transition pair ( m/z 328.8 → m/z 204.6) for internal standard.The calibration standards of valproic acid showed linear over a range from 50 to 40 000 ng/mL, with a lower limit of quantitation of 50 ng/mL with accuracy of 3.74% and precision of 5.06%. The bias for inter- and intra-batch assays was 1.24–6.14% and 3.85–11.84%, respectively; while the corresponding precision was 2.56–16.37% and 1.29–11.34%, respectively. The developed method was used to monitor valproic acid levels in clinical samples. Because of higher sensitivity, this method can be used for therapeutic drug monitoring in pediatric subjects.

Key concepts: Chromatography, Furosemide, Chemistry, Valproic Acid, Plasma, Mass spectrometry, Medicine, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
A Sensitive Triple Quadrupole Liquid Chromatography Mass Spectrometric Method for the Estimation of Valproic Acid in K2EDTA Human Plasma using Furosemide as the Internal Standard — Research Paper | ScholarLens