2015International Journal of Research in Engineering and TechnologyOpen access

DYNAMIC ANALYSIS OF STEEL TUBE STRUCTURE WITH BRACING SYSTEMS

Dhanapalagoud Patil .

Open full text 1 citations

Abstract

Nowadays, competition towards rise of tall steel structures made certain factors are compulsory like serviceability and comfort of human relating to lateral loads caused by wind or earthquake.Earthquake is dangerous to the living beings in terms of its effects on manmade structures.Structures like tall buildings are built to resist gravity loads.However many tall buildings are not so resistant in lateral loads due to earthquake so need an improvement in resisting lateral loads.So there are many structural systems which resist lateral loads by varying orientation, addition of different structural systems.Like steel tubular structural system is considered and compared for their results against lateral forces and also by providing mega bracing system and diagrid bracing system.In this dissertation work, four structural systems are considered in which one is framed structure and rest are tubular system with addition of different bracing systems as mega bracing and diagrid bracing system.For the purpose 45 storey steel structure with rectangular plan of dimension 44mx24m uniform throughout the height is considered and analyzed for gravity and lateral loads using ETABS software.Its intention is to obtain the functioning characteristics like displacements, storey shear, time period, frequency, peak displacement and peak acceleration in both x and y direction to get most economical structure in all ways.Results shows that the steel tubular structure with mega bracing system performance is much better than the framed structure, tubular and tubular structure with diagrid bracing system.

Open-access reader

About this research paper

What this paper is about

Nowadays, competition towards rise of tall steel structures made certain factors are compulsory like serviceability and comfort of human relating to lateral loads caused by wind or earthquake.Earthquake is dangerous to the living beings in terms of its effects on manmade structures.Structures like tall buildings are built to resist gravity loads.However many tall buildings are not so resistant in lateral loads due to earthquake so need an improvement in resisting lateral loads.So there are many structural systems which resist lateral loads by varying orientation, addition of different structural systems.Like steel tubular structural system is considered and compared for their results against lateral forces and also by providing mega bracing system and diagrid bracing system.In this dissertation work, four structural systems are considered in which one is framed structure and rest are tubular system with addition of different bracing systems as mega bracing and diagrid bracing system.For the purpose 45 storey steel structure with rectangular plan of dimension 44mx24m uniform throughout the height is considered and analyzed for gravity and lateral loads using ETABS software.Its intention is to obtain the functioning characteristics like displacements, storey shear, time period, frequency, peak displacement and peak acceleration in both x and y direction to get most economical structure in all ways.Results shows that the steel tubular structure with mega bracing system performance is much better than the framed structure, tubular and tubular structure with diagrid bracing system.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Nowadays, competition towards rise of tall steel structures made certain factors are compulsory like serviceability and comfort of human relating to lateral loads caused by wind or earthquake.Earthquake is dangerous to the living beings in terms of its effects on manmade structures.Structures like tall buildings are built to resist gravity loads.However many tall buildings are not so resistant in lateral loads due to earthquake so need an improvement in resisting lateral loads.So there are many structural systems which resist lateral loads by varying orientation, addition of different structural systems.Like steel tubular structural system is considered and compared for their results against lateral forces and also by providing mega bracing system and diagrid bracing system.In this dissertation work, four structural systems are considered in which one is framed structure and rest are tubular system with addition of different bracing systems as mega bracing and diagrid bracing system.For the purpose 45 storey steel structure with rectangular plan of dimension 44mx24m uniform throughout the height is considered and analyzed for gravity and lateral loads using ETABS software.Its intention is to obtain the functioning characteristics like displacements, storey shear, time period, frequency, peak displacement and peak acceleration in both x and y direction to get most economical structure in all ways.Results shows that the steel tubular structure with mega bracing system performance is much better than the framed structure, tubular and tubular structure with diagrid bracing system.

Key concepts: Bracing, Tube (container), Structural engineering, Materials science, Engineering, Mechanical engineering, Brace

Related papers

Back to paper searchBrowse research topicsOriginal source
DYNAMIC ANALYSIS OF STEEL TUBE STRUCTURE WITH BRACING SYSTEMS — Research Paper | ScholarLens