2016Pediatric Critical Care MedicineRequires access

A Randomized Controlled Comparison of the Internal Jugular Vein and the Subclavian Vein as Access Sites for Central Venous Catheterization in Pediatric Cardiac Surgery

Aynur Camkıran Fırat, Pınar Zeyneloğlu, Murat Özkan, Arash Pirat

Open publisher page 35 citations

Abstract

OBJECTIVES: To compare internal jugular vein and subclavian vein access for central venous catheterization in terms of success rate and complications. DESIGN: A 1:1 randomized controlled trial. SETTING: Baskent University Medical Center. PATIENTS: Pediatric patients scheduled for cardiac surgery. INTERVENTIONS: Two hundred and eighty children undergoing central venous catheterization were randomly allocated to the internal jugular vein or subclavian vein group during a period of 18 months. MEASUREMENTS AND MAIN RESULTS: The primary outcome was the first-attempt success rate of central venous catheterization through either approach. The secondary outcomes were the rates of infectious and mechanical complications. The central venous catheterization success rate at the first attempt was not significantly different between the subclavian vein (69%) and internal jugular vein (64%) groups (p = 0.448). However, the overall success rate was significantly higher through the subclavian vein (91%) than the internal jugular vein (82%) (p = 0.037). The overall frequency of mechanical complications was not significantly different between the internal jugular vein (25%) and subclavian vein (31%) (p = 0.456). However, the rate of arterial puncture was significantly higher with internal jugular vein (8% vs 2%; p = 0.03) and that of catheter malposition was significantly higher with subclavian vein (17% vs 1%; p < 0.001). The rates per 1,000 catheter days for both positive catheter-tip cultures (26.1% vs 3.6%; p < 0.001) and central-line bloodstream infection (6.9 vs 0; p < 0.001) were significantly higher with internal jugular vein. There were no significant differences between the groups in the length of ICU and hospital stays or in-hospital mortality rates (p > 0.05 for all). CONCLUSIONS: Central venous catheterization through the internal jugular vein and subclavian vein was not significantly different in terms of success at the first attempt. Although the types of mechanical complications were different, the overall rate was similar between internal jugular vein and subclavian vein access. The risk of infectious complications was significantly higher with internal jugular vein access.

About this research paper

What this paper is about

OBJECTIVES: To compare internal jugular vein and subclavian vein access for central venous catheterization in terms of success rate and complications. DESIGN: A 1:1 randomized controlled trial. SETTING: Baskent University Medical Center. PATIENTS: Pediatric patients scheduled for cardiac surgery. INTERVENTIONS: Two hundred and eighty children undergoing central venous catheterization were randomly allocated to the internal jugular vein or subclavian vein group during a period of 18 months. MEASUREMENTS AND MAIN RESULTS: The primary outcome was the first-attempt success rate of central venous catheterization through either approach. The secondary outcomes were the rates of infectious and mechanical complications. The central venous catheterization success rate at the first attempt was not significantly different between the subclavian vein (69%) and internal jugular vein (64%) groups (p = 0.448). However, the overall success rate was significantly higher through the subclavian vein (91%) than the internal jugular vein (82%) (p = 0.037). The overall frequency of mechanical complications was not significantly different between the internal jugular vein (25%) and subclavian vein (31%) (p = 0.456). However, the rate of arterial puncture was significantly higher with internal jugular vein (8% vs 2%; p = 0.03) and that of catheter malposition was significantly higher with subclavian vein (17% vs 1%; p < 0.001). The rates per 1,000 catheter days for both positive catheter-tip cultures (26.1% vs 3.6%; p < 0.001) and central-line bloodstream infection (6.9 vs 0; p < 0.001) were significantly higher with internal jugular vein. There were no significant differences between the groups in the length of ICU and hospital stays or in-hospital mortality rates (p > 0.05 for all). CONCLUSIONS: Central venous catheterization through the internal jugular vein and subclavian vein was not significantly different in terms of success at the first attempt. Although the types of mechanical complications were different, the overall rate was similar between internal jugular vein and subclavian vein access. The risk of infectious complications was significantly higher with internal jugular vein access.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: To compare internal jugular vein and subclavian vein access for central venous catheterization in terms of success rate and complications. DESIGN: A 1:1 randomized controlled trial. SETTING: Baskent University Medical Center. PATIENTS: Pediatric patients scheduled for cardiac surgery. INTERVENTIONS: Two hundred and eighty children undergoing central venous catheterization were randomly allocated to the internal jugular vein or subclavian vein group during a period of 18 months. MEASUREMENTS AND MAIN RESULTS: The primary outcome was the first-attempt success rate of central venous catheterization through either approach. The secondary outcomes were the rates of infectious and mechanical complications. The central venous catheterization success rate at the first attempt was not significantly different between the subclavian vein (69%) and internal jugular vein (64%) groups (p = 0.448). However, the overall success rate was significantly higher through the subclavian vein (91%) than the internal jugular vein (82%) (p = 0.037). The overall frequency of mechanical complications was not significantly different between the internal jugular vein (25%) and subclavian vein (31%) (p = 0.456). However, the rate of arterial puncture was significantly higher with internal jugular vein (8% vs 2%; p = 0.03) and that of catheter malposition was significantly higher with subclavian vein (17% vs 1%; p < 0.001). The rates per 1,000 catheter days for both positive catheter-tip cultures (26.1% vs 3.6%; p < 0.001) and central-line bloodstream infection (6.9 vs 0; p < 0.001) were significantly higher with internal jugular vein. There were no significant differences between the groups in the length of ICU and hospital stays or in-hospital mortality rates (p > 0.05 for all). CONCLUSIONS: Central venous catheterization through the internal jugular vein and subclavian vein was not significantly different in terms of success at the first attempt. Although the types of mechanical complications were different, the overall rate was similar between internal jugular vein and subclavian vein access. The risk of infectious complications was significantly higher with internal jugular vein access.

Key concepts: Medicine, Internal jugular vein, Subclavian vein, Catheter, Surgery, Vein, Jugular vein, Randomized controlled trial

Related papers

Back to paper searchBrowse research topicsOriginal source
A Randomized Controlled Comparison of the Internal Jugular Vein and the Subclavian Vein as Access Sites for Central Venous Catheterization in Pediatric Cardiac Surgery — Research Paper | ScholarLens