Clinical Observation of the Position of Central Venous Catheter Aided with the Intravenous ECG Via Subclavian Vein

Jingjing Liu

Open publisher page 0 citations

Abstract

Objective: To evaluate the possibility of IVECG as a simple and reliable technique to monitoring the position of the catheter.Methods:80 adult patients scheduled for elective major surgeries and central venous catheterizations under general anesthesia were randomly divided into two groups,with 40 cases in each group.Patients all received right subclavian vein catheterization through the supraclaricular approach below right subclavian thyroid notch 1.0-1.5 cm.Patients in Group A received routine method,the depth of the catheter(L)=(H/10)-2;Patients in Group B adjusted the depth of the catheter based on the characters of IVECG.The position of the catheter was reassured by using posterior-anterior position X-ray examination after operation.Results:The depth of the catheter was(15.1±1.2)cm,(13.4±0.9)cm respectively;the rate of satisfactory catheter tip placement were 80% and 100% respectively.There were obvious statistical significance between the two groups(P0.05).Conclusion:Application of the catheter based on the characters of IVECG can monitor the variation of the depth of the catheter and also provide valuable information about the catheter that fails to be placed into the superior vena cava.It also can reduce costs associated with repositioning procedures.The technique is easy and safe to apply and should be widely used.

About this research paper

What this paper is about

Objective: To evaluate the possibility of IVECG as a simple and reliable technique to monitoring the position of the catheter.Methods:80 adult patients scheduled for elective major surgeries and central venous catheterizations under general anesthesia were randomly divided into two groups,with 40 cases in each group.Patients all received right subclavian vein catheterization through the supraclaricular approach below right subclavian thyroid notch 1.0-1.5 cm.Patients in Group A received routine method,the depth of the catheter(L)=(H/10)-2;Patients in Group B adjusted the depth of the catheter based on the characters of IVECG.The position of the catheter was reassured by using posterior-anterior position X-ray examination after operation.Results:The depth of the catheter was(15.1±1.2)cm,(13.4±0.9)cm respectively;the rate of satisfactory catheter tip placement were 80% and 100% respectively.There were obvious statistical significance between the two groups(P0.05).Conclusion:Application of the catheter based on the characters of IVECG can monitor the variation of the depth of the catheter and also provide valuable information about the catheter that fails to be placed into the superior vena cava.It also can reduce costs associated with repositioning procedures.The technique is easy and safe to apply and should be widely used.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To evaluate the possibility of IVECG as a simple and reliable technique to monitoring the position of the catheter.Methods:80 adult patients scheduled for elective major surgeries and central venous catheterizations under general anesthesia were randomly divided into two groups,with 40 cases in each group.Patients all received right subclavian vein catheterization through the supraclaricular approach below right subclavian thyroid notch 1.0-1.5 cm.Patients in Group A received routine method,the depth of the catheter(L)=(H/10)-2;Patients in Group B adjusted the depth of the catheter based on the characters of IVECG.The position of the catheter was reassured by using posterior-anterior position X-ray examination after operation.Results:The depth of the catheter was(15.1±1.2)cm,(13.4±0.9)cm respectively;the rate of satisfactory catheter tip placement were 80% and 100% respectively.There were obvious statistical significance between the two groups(P0.05).Conclusion:Application of the catheter based on the characters of IVECG can monitor the variation of the depth of the catheter and also provide valuable information about the catheter that fails to be placed into the superior vena cava.It also can reduce costs associated with repositioning procedures.The technique is easy and safe to apply and should be widely used.

Key concepts: Medicine, Subclavian vein, Catheter, Surgery, Superior vena cava, Central venous catheter, Vein, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical Observation of the Position of Central Venous Catheter Aided with the Intravenous ECG Via Subclavian Vein — Research Paper | ScholarLens