2000Nihon Kessho GakkaishiOpen access

SPring-8, What can we do now? Third Generation XAFS Using Tunable X-Ray Undulator at BL10XU of SPring-8. Another Paradime with High Brilliance Photon Source.

H. Ōyanagi, Masashi Ishii, Chul‐Ho Lee, N. L. Saini, Yuji Kuwahara, Akira Saito, Hideki Hashimoto, Yasuo Izumi

Open full text 0 citations

Abstract

We report on the initial test of undulator tuning for the beamline BL10XU at Spring-8. The optics of BL10XU is quite simple, i.e., major optical components are a rotated-inclined double crystal monochromator designed by Ishikawa and a double flat mirror. One of a standard in-vacuum type undulator (U032V) is used. Since a typical energy range of - 1 keV is required as a routine EXAFS scan, both monochromator and undulator gap should be controlled during a scan; an undulator gap is varied so that a monochromator acceptance can track the undulator peak. On varying an undulator gap from 9.6 mm to 22 mm, a wide energy range (5-30 keV) is covered. We demonstrate that undulator tuning can provide glitch-free transmission spectra with a high energy resolution (1.5 eV at 9 keV) .

Open-access reader

About this research paper

What this paper is about

We report on the initial test of undulator tuning for the beamline BL10XU at Spring-8. The optics of BL10XU is quite simple, i.e., major optical components are a rotated-inclined double crystal monochromator designed by Ishikawa and a double flat mirror. One of a standard in-vacuum type undulator (U032V) is used. Since a typical energy range of - 1 keV is required as a routine EXAFS scan, both monochromator and undulator gap should be controlled during a scan; an undulator gap is varied so that a monochromator acceptance can track the undulator peak. On varying an undulator gap from 9.6 mm to 22 mm, a wide energy range (5-30 keV) is covered. We demonstrate that undulator tuning can provide glitch-free transmission spectra with a high energy resolution (1.5 eV at 9 keV) .

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We report on the initial test of undulator tuning for the beamline BL10XU at Spring-8. The optics of BL10XU is quite simple, i.e., major optical components are a rotated-inclined double crystal monochromator designed by Ishikawa and a double flat mirror. One of a standard in-vacuum type undulator (U032V) is used. Since a typical energy range of - 1 keV is required as a routine EXAFS scan, both monochromator and undulator gap should be controlled during a scan; an undulator gap is varied so that a monochromator acceptance can track the undulator peak. On varying an undulator gap from 9.6 mm to 22 mm, a wide energy range (5-30 keV) is covered. We demonstrate that undulator tuning can provide glitch-free transmission spectra with a high energy resolution (1.5 eV at 9 keV) .

Key concepts: Undulator, Monochromator, SPring-8, Beamline, Optics, Physics, Photon energy, Collimator

Related papers

Back to paper searchBrowse research topicsOriginal source
SPring-8, What can we do now? Third Generation XAFS Using Tunable X-Ray Undulator at BL10XU of SPring-8. Another Paradime with High Brilliance Photon Source. — Research Paper | ScholarLens