1996Review of Scientific InstrumentsRequires access

Spatial imaging of monochromatic hard x-rays from an APS undulator by the Kohzu double-crystal monochromator (abstract)

Dennis M. Mills, W.K. Lee, M. Keeffe, D. R. Haeffner, P.B. Fernandez

Open publisher page 0 citations

Abstract

The spatial distribution of monochromatic x-rays produced by an APS undulator was imaged on a fluorescent screen and recorded with a video camera while commissioning the Kohzu double-crystal monochromator (DCM). Two sets of images were recorded: Case 1 in which the spectral output of the undulator is fixed (constant magnetic gap) and the monochromator is scanned in energy, and Case 2 in which the monochromator energy is held fixed and the spectral output of the undulator is varied by changing the magnetic gap of the insertion device. Because of the performance of the Kohzu monochromator, the mechanical conditions required to maintain the twice-diffracted beam could be preserved as the DCM was scanned in energy, allowing the evolution as a function of energy. The images are compared with the calculated spatial distributions of monochromatic undulator radiation.

About this research paper

What this paper is about

The spatial distribution of monochromatic x-rays produced by an APS undulator was imaged on a fluorescent screen and recorded with a video camera while commissioning the Kohzu double-crystal monochromator (DCM). Two sets of images were recorded: Case 1 in which the spectral output of the undulator is fixed (constant magnetic gap) and the monochromator is scanned in energy, and Case 2 in which the monochromator energy is held fixed and the spectral output of the undulator is varied by changing the magnetic gap of the insertion device. Because of the performance of the Kohzu monochromator, the mechanical conditions required to maintain the twice-diffracted beam could be preserved as the DCM was scanned in energy, allowing the evolution as a function of energy. The images are compared with the calculated spatial distributions of monochromatic undulator radiation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The spatial distribution of monochromatic x-rays produced by an APS undulator was imaged on a fluorescent screen and recorded with a video camera while commissioning the Kohzu double-crystal monochromator (DCM). Two sets of images were recorded: Case 1 in which the spectral output of the undulator is fixed (constant magnetic gap) and the monochromator is scanned in energy, and Case 2 in which the monochromator energy is held fixed and the spectral output of the undulator is varied by changing the magnetic gap of the insertion device. Because of the performance of the Kohzu monochromator, the mechanical conditions required to maintain the twice-diffracted beam could be preserved as the DCM was scanned in energy, allowing the evolution as a function of energy. The images are compared with the calculated spatial distributions of monochromatic undulator radiation.

Key concepts: Monochromator, Undulator, Monochromatic color, Optics, Physics, Synchrotron radiation, Radiation, Wavelength

Related papers

Back to paper searchBrowse research topicsOriginal source
Spatial imaging of monochromatic hard x-rays from an APS undulator by the Kohzu double-crystal monochromator (abstract) — Research Paper | ScholarLens