Haemodynamic Response To Laryngoscopy And Intubation: Comparison Of McCoy And Macintosh Laryngoscope
Author information unavailable
Abstract
Author information unavailable
Abstract
A prospective randomized study was done to compare hemodynamic response to laryngoscopy and intubation using McCoy and Macintosh laryngoscope. Hundred patients of either sex, belonging to ASA grade I or II, between age group of 20-50 years, requiring general anaesthesia with intubation were included in the study. A standard anaesthesia technique was used in all the patients. Both the groups (n=50) were matched demographically. Mallampati grading, laryngoscopy and intubation time and laryngeal visualization grades were comparable. Hemodynamic variables at baseline and following induction were also statistically comparable. Following laryngoscopy there was statistically significant rise in HR, SBP, DBP and MAP in both the groups (31.32±6.96 bpm, 37.78±6.72mmHg, 36.18±7.95mmHg, 31.84±6.94mmHg in group A and 21.04±6.60 bpm, 18.16±4.75mmHg, 19.14±4.91mmHg, 18.48±5.97mmHg in group B respectively). A further rise was seen in all variables following intubation, which persisted till one minute after intubation. Increase in hemodynamic variables was statistically highly significant with Macintosh laryngoscope as compared to McCoy. It was concluded that McCoy laryngoscope produces significantly less marked hemodynamic response.
OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A prospective randomized study was done to compare hemodynamic response to laryngoscopy and intubation using McCoy and Macintosh laryngoscope. Hundred patients of either sex, belonging to ASA grade I or II, between age group of 20-50 years, requiring general anaesthesia with intubation were included in the study. A standard anaesthesia technique was used in all the patients. Both the groups (n=50) were matched demographically. Mallampati grading, laryngoscopy and intubation time and laryngeal visualization grades were comparable. Hemodynamic variables at baseline and following induction were also statistically comparable. Following laryngoscopy there was statistically significant rise in HR, SBP, DBP and MAP in both the groups (31.32±6.96 bpm, 37.78±6.72mmHg, 36.18±7.95mmHg, 31.84±6.94mmHg in group A and 21.04±6.60 bpm, 18.16±4.75mmHg, 19.14±4.91mmHg, 18.48±5.97mmHg in group B respectively). A further rise was seen in all variables following intubation, which persisted till one minute after intubation. Increase in hemodynamic variables was statistically highly significant with Macintosh laryngoscope as compared to McCoy. It was concluded that McCoy laryngoscope produces significantly less marked hemodynamic response.
Key concepts: Medicine, Laryngoscopy, Intubation, Anesthesia, Haemodynamic response, Laryngoscopes, Hemodynamics, Internal medicine