2020Journal of Anaesthesiology Clinical PharmacologyOpen access

Evaluation of King's vision videolaryngoscope and glidescope on hemodynamic stress response to laryngoscopy and endotracheal intubation

NagatS EL-Shmaa

Open full text 5 citations

Abstract

BACKGROUND AND AIMS: We hypothesis that the use of novel airway devices would decrease hemodynamic stress response (HDSR) to laryngoscopy and endotracheal (ET) intubation. The aim of our study was to evaluate the hemodynamic stress response (HDSR) to laryngoscopy and tracheal intubation using the King vision video laryngoscope (KVVL) versus glidescope (GLS). MATERIAL AND METHODS: A prospective randomized, comparative study that was conducted on 80 patients of both sexes; American Society of Anesthesiologists physical status I and II with no anticipated difficult airway, aged 20-60 years; who were scheduled for elective surgical procedure under general anesthesia. Patients were randomly allocated into two groups (40 each). Group I: laryngoscopy and tracheal intubation were carried out using KVVL, Group II: laryngoscopy and tracheal intubation were carried out using GLS. The two groups were compared for noninvasive hemodynamic data such as heart rate and mean arterial pressure. Time to successful intubation and number of attempts were recorded. Hemodynamic parameters were recorded at the preinduction, after induction, at intubation, 1 min, 3 min, 5 min, 10 min, and 15 min. RESULTS: < 0.05) in HR and MBP in both groups just before intubation. In comparison with the baseline, HR and MBP in group I and group II increased but this difference was not significant at 3 min and 5 min after intubation and returned to the baseline at 10 min after intubation and below the baseline at 15 min after intubation. Also, there were no significant differences in the hemodynamic response between the studied groups. CONCLUSION: Novel airway devices either KVVL or GLS are efficient in reducing HDSR to laryngoscopy and ET intubation.

About this research paper

What this paper is about

BACKGROUND AND AIMS: We hypothesis that the use of novel airway devices would decrease hemodynamic stress response (HDSR) to laryngoscopy and endotracheal (ET) intubation. The aim of our study was to evaluate the hemodynamic stress response (HDSR) to laryngoscopy and tracheal intubation using the King vision video laryngoscope (KVVL) versus glidescope (GLS). MATERIAL AND METHODS: A prospective randomized, comparative study that was conducted on 80 patients of both sexes; American Society of Anesthesiologists physical status I and II with no anticipated difficult airway, aged 20-60 years; who were scheduled for elective surgical procedure under general anesthesia. Patients were randomly allocated into two groups (40 each). Group I: laryngoscopy and tracheal intubation were carried out using KVVL, Group II: laryngoscopy and tracheal intubation were carried out using GLS. The two groups were compared for noninvasive hemodynamic data such as heart rate and mean arterial pressure. Time to successful intubation and number of attempts were recorded. Hemodynamic parameters were recorded at the preinduction, after induction, at intubation, 1 min, 3 min, 5 min, 10 min, and 15 min. RESULTS: < 0.05) in HR and MBP in both groups just before intubation. In comparison with the baseline, HR and MBP in group I and group II increased but this difference was not significant at 3 min and 5 min after intubation and returned to the baseline at 10 min after intubation and below the baseline at 15 min after intubation. Also, there were no significant differences in the hemodynamic response between the studied groups. CONCLUSION: Novel airway devices either KVVL or GLS are efficient in reducing HDSR to laryngoscopy and ET intubation.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND AND AIMS: We hypothesis that the use of novel airway devices would decrease hemodynamic stress response (HDSR) to laryngoscopy and endotracheal (ET) intubation. The aim of our study was to evaluate the hemodynamic stress response (HDSR) to laryngoscopy and tracheal intubation using the King vision video laryngoscope (KVVL) versus glidescope (GLS). MATERIAL AND METHODS: A prospective randomized, comparative study that was conducted on 80 patients of both sexes; American Society of Anesthesiologists physical status I and II with no anticipated difficult airway, aged 20-60 years; who were scheduled for elective surgical procedure under general anesthesia. Patients were randomly allocated into two groups (40 each). Group I: laryngoscopy and tracheal intubation were carried out using KVVL, Group II: laryngoscopy and tracheal intubation were carried out using GLS. The two groups were compared for noninvasive hemodynamic data such as heart rate and mean arterial pressure. Time to successful intubation and number of attempts were recorded. Hemodynamic parameters were recorded at the preinduction, after induction, at intubation, 1 min, 3 min, 5 min, 10 min, and 15 min. RESULTS: < 0.05) in HR and MBP in both groups just before intubation. In comparison with the baseline, HR and MBP in group I and group II increased but this difference was not significant at 3 min and 5 min after intubation and returned to the baseline at 10 min after intubation and below the baseline at 15 min after intubation. Also, there were no significant differences in the hemodynamic response between the studied groups. CONCLUSION: Novel airway devices either KVVL or GLS are efficient in reducing HDSR to laryngoscopy and ET intubation.

Key concepts: Laryngoscopy, Medicine, Intubation, Anesthesia, Hemodynamics, Haemodynamic response, Tracheal intubation, Airway management

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of King's vision videolaryngoscope and glidescope on hemodynamic stress response to laryngoscopy and endotracheal intubation — Research Paper | ScholarLens