1995•Unpublished venueOpen access
A concept of JAERI passive safety light water reactor system (JPSR)
Nuclear Regulatory Commission, Washington, DC (United States). Div. of Systems Technology, Y. Murao, American Nuclear Society, La Grange Park, IL (United States), American Inst. of Chemical Engineers, New York, NY (United States), American Society of Mechanical Engineers, New York, NY (United States), Canadian Nuclear Society, Toronto, ON (Canada), Bern (Switzerland) European Nuclear Society (ENS), Tokyo (Japan) Atomic Energy Society of Japan, Kyoto (Japan) Japan Society of Multiphase Flow, F. Araya, T. Iwamura
Abstract
The Japan Atomic Energy Research Institute (JAERI) proposed a passive safety reactor system concept, JPSR, which was developed for reducing manpower in operation and maintenance and influence of human errors on reactor safety. In the concept the system was extremely simplified. The inherent matching nature of core generation and heat removal rate within a small volume change of the primary coolant is introduced by eliminating chemical shim and adopting in-vessel control rod drive mechanism units, a low power density core and once-through steam generators. In order to simplify the system, a large pressurizer, canned pumps, passive engineered-safety-features-system (residual heat removal system and coolant injection system) are adopted and the total system can be significantly simplified. The residual heat removal system is completely passively actuated in non-LOCAs and is also used for depressurization of the primary coolant system to actuate accumulators in small break LOCAs and reactor shutdown cooling system in normal operation. All of systems for nuclear steam supply system are built in the containment except for the air coolers as a the final heat sink of the passive residual heat removal system. Accordingly the reliability of the safety system and the normal operation system is improved, since most of residual heat removal system is always working and a heat sink for normal operation system is {open_quotes}safety class{close_quotes}. In the passive coolant injection system, depressurization of the primary cooling system by residual heat removal system initiates injection from accumulators designed for the MS-600 in medium pressure and initiates injection from the gravity driven coolant injection pool at low pressure. Analysis with RETRAN-02/MOD3 code demonstrated the capability of passive load-following, self-power-controllability, cooling and depressurization.