1997•PubMedRequires access

[Reproducibility of regional cerebral blood flow measurement at rest with autoradiography method using 123I-IMP and SPECT].

Koji Saito, Hajime Murata, Hirotaka Maruno, Koichi Mori, Shohei Tsuchida

Open publisher page 1 citations

Abstract

Reproducibility of regional cerebral blood flow (rCBF) values obtained by the autoradiography (ARG) method with one SPECT scan and one point arterial blood sampling at 10 min after 123I-N-isopropyl-p-iodoamphetamine (IMP) infusion was evaluated. The variation in the cross calibration factor between SPECT counts and well-type scintillation counts remained 2.2% for 13 months. The error in rCBF by sampling time difference was less than 3% when sampling time was within 10 min +/- 30 sec after infusion. There was a favorable correlation between the rCBF values in two separate resting scans measured by the ARG method in 10 patients (r = 0.907). And the mean ratio of rCBF values by the second study to those by the first study in the cerebellum and cerebral lobes in 10 patients was 0.989 +/- 0.056 (mean +/- SD). There was no significant difference in rCBF values between two separate studies. Reproducibility of rCBF with the ARG method was proved to be good. The ARG method was thought to be useful for the assessment of treatment effects and clinical courses.

About this research paper

What this paper is about

Reproducibility of regional cerebral blood flow (rCBF) values obtained by the autoradiography (ARG) method with one SPECT scan and one point arterial blood sampling at 10 min after 123I-N-isopropyl-p-iodoamphetamine (IMP) infusion was evaluated. The variation in the cross calibration factor between SPECT counts and well-type scintillation counts remained 2.2% for 13 months. The error in rCBF by sampling time difference was less than 3% when sampling time was within 10 min +/- 30 sec after infusion. There was a favorable correlation between the rCBF values in two separate resting scans measured by the ARG method in 10 patients (r = 0.907). And the mean ratio of rCBF values by the second study to those by the first study in the cerebellum and cerebral lobes in 10 patients was 0.989 +/- 0.056 (mean +/- SD). There was no significant difference in rCBF values between two separate studies. Reproducibility of rCBF with the ARG method was proved to be good. The ARG method was thought to be useful for the assessment of treatment effects and clinical courses.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Reproducibility of regional cerebral blood flow (rCBF) values obtained by the autoradiography (ARG) method with one SPECT scan and one point arterial blood sampling at 10 min after 123I-N-isopropyl-p-iodoamphetamine (IMP) infusion was evaluated. The variation in the cross calibration factor between SPECT counts and well-type scintillation counts remained 2.2% for 13 months. The error in rCBF by sampling time difference was less than 3% when sampling time was within 10 min +/- 30 sec after infusion. There was a favorable correlation between the rCBF values in two separate resting scans measured by the ARG method in 10 patients (r = 0.907). And the mean ratio of rCBF values by the second study to those by the first study in the cerebellum and cerebral lobes in 10 patients was 0.989 +/- 0.056 (mean +/- SD). There was no significant difference in rCBF values between two separate studies. Reproducibility of rCBF with the ARG method was proved to be good. The ARG method was thought to be useful for the assessment of treatment effects and clinical courses.

Key concepts: Reproducibility, Cerebral blood flow, Nuclear medicine, Medicine, Blood sampling, Mean difference, Chemistry, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
[Reproducibility of regional cerebral blood flow measurement at rest with autoradiography method using 123I-IMP and SPECT]. — Research Paper | ScholarLens