2002PubMedRequires access

[Determination of ascorbic acid by suppressed chemiluminescence].

Quanli Ma, Yongping Jin, Hong-tao You, Huimin Ma

Open publisher page 1 citations

Abstract

This paper describes a method for determining ascorbic acid by the suppression of DTMC-H2O2 chemiluminescence. Various factors affecting the chemiluminescence determination of ascorbic acid were examined. Under the optimal conditions (1.2 x 10(-4) mol.L-1 of DTMC, 5.0 x 10(-5) mol.L-1 of H2O2, and pH 11.4 Na2HPO4-NaOH), the quenching of the chemiluminescent intensity was proportional to the concentration of ascorbic acid in the range of 1.0 x 10(-7)-8.0 x 10(-6) mol.L-1, and the detection limit was 8.0 x 10(-8) mol.L-1 (S/N = 3). The RSD was 4.6% for 1.0 x 10(-6) mol.L-1 of ascorbic acid (n = 10). The selectivity of this method was high and no making agent required. The proposed method has been applied to the determination of ascorbic acid in real samples. The obtained results were in agreement with those by CuSO4-KI titration.

About this research paper

What this paper is about

This paper describes a method for determining ascorbic acid by the suppression of DTMC-H2O2 chemiluminescence. Various factors affecting the chemiluminescence determination of ascorbic acid were examined. Under the optimal conditions (1.2 x 10(-4) mol.L-1 of DTMC, 5.0 x 10(-5) mol.L-1 of H2O2, and pH 11.4 Na2HPO4-NaOH), the quenching of the chemiluminescent intensity was proportional to the concentration of ascorbic acid in the range of 1.0 x 10(-7)-8.0 x 10(-6) mol.L-1, and the detection limit was 8.0 x 10(-8) mol.L-1 (S/N = 3). The RSD was 4.6% for 1.0 x 10(-6) mol.L-1 of ascorbic acid (n = 10). The selectivity of this method was high and no making agent required. The proposed method has been applied to the determination of ascorbic acid in real samples. The obtained results were in agreement with those by CuSO4-KI titration.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper describes a method for determining ascorbic acid by the suppression of DTMC-H2O2 chemiluminescence. Various factors affecting the chemiluminescence determination of ascorbic acid were examined. Under the optimal conditions (1.2 x 10(-4) mol.L-1 of DTMC, 5.0 x 10(-5) mol.L-1 of H2O2, and pH 11.4 Na2HPO4-NaOH), the quenching of the chemiluminescent intensity was proportional to the concentration of ascorbic acid in the range of 1.0 x 10(-7)-8.0 x 10(-6) mol.L-1, and the detection limit was 8.0 x 10(-8) mol.L-1 (S/N = 3). The RSD was 4.6% for 1.0 x 10(-6) mol.L-1 of ascorbic acid (n = 10). The selectivity of this method was high and no making agent required. The proposed method has been applied to the determination of ascorbic acid in real samples. The obtained results were in agreement with those by CuSO4-KI titration.

Key concepts: Ascorbic acid, Chemiluminescence, Chemistry, Detection limit, Titration, Chromatography, Quenching (fluorescence), Nuclear chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of ascorbic acid by suppressed chemiluminescence]. — Research Paper | ScholarLens