Evidence for the safety of coumaphos, diazinon and malathion residues in honey.
Fernandez Garcia, M. J. Melgar, Carlos Herrero, Garcia Fernandez Mi
Abstract
Fernandez Garcia, M. J. Melgar, Carlos Herrero, Garcia Fernandez Mi
Abstract
Residue levels of coumaphos, diazinon and malathion in honey were analysed in 177 samples of honey collected from different regions of Lugo in NW Spain in 1988-1990. One has to expect some of them as residues in honey, even if employed properly, for example coumaphos used against the parasitic mite Varroa jacobsoni. Honey samples were extracted with acetonitrile:water (2:1 v/v), partitioned with petroleum-ether, cleaned up with a manual Florisil column or Florisil Sep-Pack, evaporated to dryness, redissolved in an appropriate volume (1 mL) and then analyzed by GLC with a silica capillary column and nitrogen-phosphorus detector. Recoveries of coumaphos, diazinon and malathion varied between 80-97%. One hundred forty-eight samples contained no detectable residues, while 29 had residues of coumaphos and diazinon in ppb levels. These residues are minimal and when eating honey are harmless for the health of human beings.
OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Residue levels of coumaphos, diazinon and malathion in honey were analysed in 177 samples of honey collected from different regions of Lugo in NW Spain in 1988-1990. One has to expect some of them as residues in honey, even if employed properly, for example coumaphos used against the parasitic mite Varroa jacobsoni. Honey samples were extracted with acetonitrile:water (2:1 v/v), partitioned with petroleum-ether, cleaned up with a manual Florisil column or Florisil Sep-Pack, evaporated to dryness, redissolved in an appropriate volume (1 mL) and then analyzed by GLC with a silica capillary column and nitrogen-phosphorus detector. Recoveries of coumaphos, diazinon and malathion varied between 80-97%. One hundred forty-eight samples contained no detectable residues, while 29 had residues of coumaphos and diazinon in ppb levels. These residues are minimal and when eating honey are harmless for the health of human beings.
Key concepts: Coumaphos, Diazinon, Malathion, Chemistry, Chromatography, Residue (chemistry), Pesticide, Electron capture detector